Vickers D03 Solenoid Valve

02-147424

Vickers D03 Solenoid Valve
Item #102039440
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Center Position P Blocked, A & B to T
Port T Code 7
Solenoid Code HL
Design No. 60
Electrical Connection DIN 43650
Coil Type ISO 4400
Temperature Range [Max] 158 °F
Compatible Fluids Petroleum Oil
Mounting Subplate/Manifold Mount
Manual Override Option Code None
No. of Stages Single Stage
Coil Rating Code HL
Leakage Standard Performance
Seal Material Buna-N
Spool Spring Arrangement Code A
Cycle Rate [Max] N/A
Overrides No Overrides
Port T Pressure Rating 3000 psi
Function Code 6
Coil Type Code U
Temperature Range [Min] -4 °F
Crossover P Blocked, A or B to T
Spool Code 6
Port Restrictor Plugs None
Surge Suppressor/Damper None
Model No. DG4V 3 6AL M U HL7 60
Actuation Identification Solenoid A
Response Time 28 to 45 ms
Housing Code None
Pilot Valve Type N/A
Reducer Module No
Pressure Port Check Valve Pressure N/A
Manual Override Plain Override
Electrical Connector Code None
Function 2-Position Spring Offset, Left Hand Build
Electrical Options None
Spool Shift Timing N/A
Actuator Type Solenoid
Port Restrictor Plug Code None
Performance High Performance
NFPA Size D03
Body Material Gray Iron
Mechanical Options None
Solenoid Energization Code None
EN Code None
Valve Type High-Performance
Solenoid Indicator Lights Code None
Response Type Standard Response
Pressure [Max] 5000 psi
Rated Flow [Max] 20 gal/min
Indicator Lights No
Spool Indicator Switch Code None
Operation Solenoid Operated
Watt Rating 18 W
Fluid Cleanliness 19/17/14 micron
Voltage & Frequency 24 VDC
Pilot/Drain None
Tank Port Rating 3046
Solenoid Single
AC/DC DC
Surge Suppressor/Damper Code None
Weight 5.0 LB