Vickers D03 Solenoid Valve

02-146123

Vickers D03 Solenoid Valve
Item #102039951
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to End Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Pressure [Max] 5000 psi
Center Position All Ports Blocked
Body Material Gray Iron
Temperature Range [Max] 158 °F
Spool Shift Timing N/A
Function Code 2
Solenoid Single
Electrical Connection Wired Terminal Block
Response Time 15 to 23 ms
Crossover All Ports Blocked
Actuation Identification Solenoid B
Manual Override Option Code H
Port Restrictor Plugs None
Solenoid Indicator Lights Code L
NFPA Size D03
Coil Type Code F
AC/DC AC
Pilot/Drain None
Spool Indicator Switch Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port T Pressure Rating 3000 psi
Surge Suppressor/Damper None
Model No. DG4V-3-2A-H-M-FTWL-B6-60
Valve Type High-Performance
Electrical Options None
Operation Solenoid Operated
Temperature Range [Min] -4 °F
Fluid Cleanliness 19/17/14 micron
Tank Port Rating 3046
No. of Stages Single Stage
Response Type Standard Response
Electrical Connector Code T
Housing Code W
Spool Spring Arrangement Code A
Function 2-Position Spring Offset, End to End
Seal Material Buna-N
Port Restrictor Plug Code None
Indicator Lights Yes
Solenoid Code B
Coil Rating Code B
Solenoid Energization Code None
Port T Code 6
Design No. 60
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Manual Override Plain Override
Surge Suppressor/Damper Code None
Cycle Rate [Max] N/A
Actuator Type Solenoid
Reducer Module No
Compatible Fluids Petroleum Oil
Leakage Standard Performance
Spool Code 2
EN Code None
Rated Flow [Max] 20 gal/min
Mechanical Options None
Mounting Subplate/Manifold Mount
Pilot Valve Type N/A
Overrides No Overrides
Performance High Performance
Pressure Port Check Valve Pressure N/A
Weight 5.0 LB