Skip to content Skip to navigation menu
Vickers02-138278

02-138278

Vickers D07 Solenoid Valve
Item #101994692
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D07 NFPA Size
  • Spring Centered Function
Vickers02-138278
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D07 NFPA Size
  • Spring Centered Function
Indicator Lights No
Body Material Ductile Iron
Pressure [Max] 5000 psi
Manual Override Plain Override
Pilot/Drain External Pilot/Internal Drain
Watt Rating 30 W
Temperature Range [Max] 158 °F
Tank Port Rating 3046
Mounting Subplate/Manifold Mount
Model No. DG5V-7-6C-T-M-U-H7-30
Rated Flow [Max] 95 gal/min
Spool Spring Arrangement Code C
Compatible Fluids Petroleum Oil
Actuation Identification Solenoid A, Solenoid B
Temperature Range [Min] -4 °F
NFPA Size D07
Leakage Standard Performance
Fluid Cleanliness 19/17/14 micron
Seal Material Buna-N
Coil Type ISO 4400 (Din 43650) Connector
Operation Pilot Operated
Actuator Type Solenoid
No. of Stages Two Stage
Function Spring Centered
Voltage & Frequency 24 VDC
AC/DC DC
Weight 1.0 LB