Skip to content Skip to navigation menu
Vickers D05 Solenoid Valve

02-120088

Vickers D05 Solenoid Valve
Item #101986361
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered, Double End Function
Vickers D05 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered, Double End Function

description

  • DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
  • Port connections are made by mounting the valve on a manifold or subplate containing the interface.
  • Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.

caution

  • Not recommended for steam service
Rated Flow [Max] 24 gal/min
Cycle Rate [Max] N/A
Model No. DG4S4W-013C-B-60
Response Type Standard Response
Performance Standard Performance
Body Material Gray Iron
Mounting Subplate/Manifold Mount
Design No. 60
Tank Port Rating 1000
Overrides No Overrides
Pressure [Max] 5000 psi
Electrical Options Code W
Function 3-Position Spring Centered, Double End
Pilot/Drain None
Port Restrictor Plugs None
Solenoid Double
Manual Override Plain Override
Port T Pressure Rating 1000 psi
Indicator Lights Yes
Seal Material Buna-N
Compatible Fluids Petroleum Oil
Spool Code 3
Electrical Connection KU W/ Deutsch Connector
Flow Direction Code 4
Coil Type Code None
NFPA Size D05
Surge Suppressor/Damper None
Temperature Range [Max] 122 °F
Electrical Options None
Leakage Standard Performance
Mechanical Options Code None
Pressure Port Check Valve Pressure N/A
Temperature Range [Min] 68 °F
Spool Spring Arrangement Code C
No. of Stages Single Stage
Actuation Identification Solenoid A, Solenoid B
Voltage & Frequency 110/120 VAC - 50/60 Hz
Center Position P & B Blocked, A to T
Coil Type Flying Leads
Actuator Type Solenoid
Coil Rating Code B
Reducer Module N/A
Fluid Cleanliness 19/17/14 micron
Mechanical Options None
AC/DC AC
Crossover All Ports Blocked, or P & B Blocked, A to T
Valve Type Standard-Duty
Response Time 20 to 40 ms
Operation Solenoid Operated
Pilot Valve Type N/A
Weight 1.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison