Vickers D03 Solenoid Valve
Item #101997260
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers02-110418
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Function 3-Position Detented
Pressure Port Check Valve Pressure N/A
Indicator Lights No
Port Restrictor Plug Code None
NFPA Size D03
Mounting Subplate/Manifold Mount
Temperature Range [Min] -4 °F
Function Code 2
Solenoid Double
Spool Spring Arrangement Code N
Surge Suppressor/Damper Code None
Port Restrictor Plugs None
Electrical Connection DIN 43650
No. of Stages Single Stage
Solenoid Energization Code None
Spool Shift Timing N/A
Surge Suppressor/Damper None
Tank Port Rating 3046
Center Position All Ports Blocked
Spool Code 2
Manual Override Option Code None
Rated Flow [Max] 20 gal/min
Temperature Range [Max] 158 °F
Solenoid Code BL
Coil Rating Code BL
Crossover All Ports Blocked
Spool Indicator Switch Code None
Manual Override Plain Override
Body Material Gray Iron
Leakage Standard Performance
Port T Pressure Rating 3000 psi
Overrides No Overrides
Electrical Connector Code None
Reducer Module No
Pressure [Max] 5000 psi
Pilot Valve Type N/A
Fluid Cleanliness 19/17/14 micron
Seal Material Buna-N
Compatible Fluids Petroleum Oil
Design No. 60
Operation Solenoid Operated
Housing Code None
Actuator Type Solenoid
Port T Code 6
Pilot/Drain None
Response Time 15 to 23 ms
Performance High Performance
Actuation Identification Solenoid A, Solenoid B
Model No. DG4V 3 2N M U BL6 60
Electrical Options None
Valve Type High-Performance
Voltage & Frequency 110/120 VAC - 50/60 Hz
Cycle Rate [Max] N/A
EN Code None
Coil Type Code U
Response Type Standard Response
Mechanical Options None
AC/DC AC
Coil Type ISO 4400
Solenoid Indicator Lights Code None
Weight 5.0 LB