- RV5-10 Series Relief Valve
- Pilot Operated
- C-10-2 Cavity
- Buna-N Seals
- Screw Adjustment
caution
- Always follow lock out and tag out procedures when working on conveyor systems.
- Periodic inspection is required to determine if the unit is in proper working order by inspecting and replacing the urethane seal, inspecting to see if material buildup has occurred and ensuring proper adjustment and tightness of all adjustable bolts.
- The Guardian™ is designed to help minimize the potential for danger but cannot guarantee protection in all situations or applications.
| Cracking Pressure [Max] | 2000 psi |
| Operation | Pilot Operated |
| Manufacturer Part No. | RV5-10-S-0-20/ |
| Seal Kit Buna | 565803 |
| Cage Seals | Single Backup Ring |
| Cracking Pressure [Min] | 100 psi |
| Adjustment Type | Screw |
| Type | Relief Valve |
| Flow [Max] | 30 gal/min |
| Housing Material | Cartridge Only |
| Seal Kit Viton | 566086 |
| Seal Material | Buna-N |
| Port Size | Cartridge Only |
| Cavity | C-10-2 |
| Series | RV5-10 |
| Model No. | RV5-10-S-0-20/ |
| Pressure [Max] | 5000 psi |
| Pressure Setting | 1050 psi |
| Weight | 1.0 LB |