Vickers D03 Solenoid Valve

871713

Vickers D03 Solenoid Valve
Item #101924187
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, End to Center Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Seal Material Buna-N
Electrical Options None
Port T Pressure Rating 3000 psi
Pilot/Drain None
Compatible Fluids Petroleum Oil
Solenoid Single
Voltage & Frequency 110/120 VAC - 50/60 Hz
Response Time 15 to 23 ms
Function Code 6
Valve Type High-Performance
Electrical Connection DIN 43650
Spool Code 6
Model No. DG4V 3 6B VM U B6 60
Port Restrictor Plugs None
Pressure [Max] 5000 psi
AC/DC AC
Surge Suppressor/Damper None
Electrical Connector Code None
Coil Type ISO 4400
Leakage Standard Performance
Mechanical Options None
Spool Shift Timing N/A
Solenoid Energization Code V
Crossover P Blocked, A or B to T
Operation Solenoid Operated
Surge Suppressor/Damper Code None
Rated Flow [Max] 20 gal/min
Design No. 60
NFPA Size D03
Solenoid Code B
Manual Override Option Code None
Temperature Range [Min] -4 °F
Actuation Identification Solenoid B
Tank Port Rating 3046
Port Restrictor Plug Code None
Port T Code 6
Performance High Performance
Actuator Type Solenoid
Solenoid Indicator Lights Code None
EN Code None
Pilot Valve Type N/A
Coil Type Code U
No. of Stages Single Stage
Spool Spring Arrangement Code B
Manual Override Plain Override
Spool Indicator Switch Code None
Indicator Lights No
Overrides No Overrides
Pressure Port Check Valve Pressure N/A
Housing Code None
Response Type Standard Response
Coil Rating Code B
Cycle Rate [Max] N/A
Fluid Cleanliness 19/17/14 micron
Function 2-Position Spring Offset, End to Center
Center Position P Blocked, A & B to T
Reducer Module No
Temperature Range [Max] 158 °F
Mounting Subplate/Manifold Mount
Body Material Gray Iron
Weight 5.0 LB