Vickers D03 Solenoid Valve

870290

Vickers D03 Solenoid Valve
Item #101922607
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Electrical Options None
Tank Port Rating 3046
Pressure Port Check Valve Pressure N/A
Function Code 6
No. of Stages Single Stage
Housing Code None
Pilot/Drain None
Function 3-Position Detented
Surge Suppressor/Damper None
Solenoid Energization Code None
Spool Spring Arrangement Code N
Design No. 60
NFPA Size D03
Leakage Standard Performance
Performance High Performance
Overrides No Overrides
Electrical Connector Code None
Actuator Type Solenoid
EN Code None
Rated Flow [Max] 20 gal/min
Spool Code 6
Indicator Lights No
Manual Override Option Code None
Surge Suppressor/Damper Code None
Solenoid Double
Spool Shift Timing N/A
Operation Solenoid Operated
Temperature Range [Max] 158 °F
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port Restrictor Plugs None
Crossover P Blocked, A or B to T
Port Restrictor Plug Code None
Reducer Module No
Temperature Range [Min] -4 °F
Electrical Connection DIN 43650
Compatible Fluids Petroleum Oil
Mechanical Options None
Solenoid Indicator Lights Code None
Manual Override Plain Override
Body Material Gray Iron
Actuation Identification Solenoid A, Solenoid B
Valve Type High-Performance
Mounting Subplate/Manifold Mount
Center Position P Blocked, A & B to T
Coil Type ISO 4400
Pilot Valve Type N/A
Port T Code 6
Coil Rating Code B
Response Time 15 to 23 ms
Cycle Rate [Max] N/A
Response Type Standard Response
Solenoid Code B
Port T Pressure Rating 3000 psi
AC/DC AC
Seal Material Buna-N
Spool Indicator Switch Code None
Coil Type Code U
Pressure [Max] 5000 psi
Model No. DG4V 3 6N MU B6 60
Fluid Cleanliness 19/17/14 micron
Weight 5.0 LB