- Solenoid Actuated Valve
- Solenoid Operated Operation
- D05 NFPA Size
- Single Solenoid
- 2-Position Spring Offset Function
description
- DGS4S models are direct solenoid operated directional control valves. Their primary function in a hydraulic circuit is to direct fluid flow to a work cylinder or to control the direction of rotation of a hydraulic motor.
- Port connections are made by mounting the valve on a manifold or subplate containing the interface.
- Electrical connections to the valve are made in an electrical wiring housing or by various plug-in devices. A ground terminal is provided.
caution
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
| Mounting | Subplate/Manifold Mount |
| Port Restrictor Plugs | None |
| Cycle Rate [Max] | N/A |
| Valve Type | Standard-Duty |
| Pilot Valve Type | N/A |
| Flow Direction Code | 4 |
| AC/DC | AC |
| Function | 2-Position Spring Offset |
| Temperature Range [Min] | 68 °F |
| Center Position | All Ports Blocked |
| Body Material | Gray Iron |
| Crossover | All Ports Blocked |
| Response Type | Standard Response |
| Model No. | DG4S4-012A-50-LH |
| Spool Code | 2 |
| Coil Rating Code | None |
| Leakage | Standard Performance |
| Actuator Type | Solenoid |
| Design No. | 50 |
| Spool Center Condition | B Port End |
| Seal Material | Buna-N |
| Mechanical Options Code | LH |
| No. of Stages | Single Stage |
| Pressure [Max] | 3600 psi |
| Operation | Solenoid Operated |
| Rated Flow [Max] | 20 gal/min |
| Tank Port Rating | 1000 |
| Spool Spring Arrangement Code | A |
| Surge Suppressor/Damper | None |
| Solenoid | Single |
| Electrical Connection | Ground Terminal |
| Port T Pressure Rating | 1000 psi |
| Actuation Identification | Solenoid B |
| Indicator Lights | No |
| Overrides | No Overrides |
| Solenoid Air Gap Code | None |
| NFPA Size | D05 |
| Reducer Module | No |
| Coil Type | No Coil |
| Mechanical Options | Single Solenoid Reverse Assembly |
| Temperature Range [Max] | 179.6 °F |
| Voltage & Frequency | 115 VAC - 60 Hz |
| Fluid Cleanliness | 19/17/14 micron |
| Pilot/Drain | None |
| Electrical Options | None |
| Electrical Options Code | None |
| Pressure Port Check Valve Pressure | N/A |
| Weight | 1.0 LB |