Skip to content Skip to navigation menu
Vickers by Danfoss02-394057

02-394057

Vickers D08 Solenoid Valve
Item #101896790
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-394057
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Port T Pressure Rating 5000 psi
Gauge Port SAE-4
Spool Indicator Switch Code None
AC/DC AC
Coil Type Code F
Seal Material Buna-N
Reducer Module Code None
Design No. 10
Center Position All Ports Blocked
NFPA Size D08
Function 3-Position Spring Centered
Solenoid Double
Voltage & Frequency 110/120 VAC - 50/60 Hz
Spool Spring Arrangement Code C
EN Code None
Spool Code 2
Mechanical Options Code None
Pilot Drain Code T
Housing Code W
Pilot Pressure Code None
Electrical Connector Code T
Response Type Standard Response
Coil Rating Code B
Manual Override Plain Override
Tank Port Rating 5000
Pilot Valve Type CETOP 3, High Performance
Pressure Port Check Valve Pressure N/A
Spool Control Modification Code 1
Solenoid Indicator Lights Code L
Pilot/Drain External Pilot/Internal Drain
Rated Flow [Max] 185 gal/min
Actuator Type Solenoid
Operation Pilot Operated
Indicator Lights Yes
Electrical Options None
Pilot Valve Type Code H
Manual Override Option Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Port Restrictor Plug Code None
Crossover All Ports Blocked
Electrical Options Code None
Solenoid Energization Code None
Pressure Port Check Valve Code None
Electrical Connection Wired Terminal Block
Pressure [Max] 5000 psi
Surge Suppressor/Damper None
Valve Type Standard-Duty
Model No. DG5V-8-H-2C-1-T-M-FTWL-B-10
Overrides Plain Override Solenoid Ends
Port Restrictor Plugs None
Reducer Module N/A
Gauge Ports Code None
Mechanical Options Adjust Stroke on Both Ends
Response Type Code None
Surge Suppressor/Damper Code None
Weight 35.0 LB