Vickers by Danfoss02-393498

02-393498

Vickers D08 Solenoid Valve
Item #101897479
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-393498
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Surge Suppressor/Damper Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Temperature Range [Min] -40 °F
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Compatible Fluids Petroleum Oil
Pilot/Drain Internal Pilot/Internal Drain
Solenoid Energization Code None
Mounting Subplate/Manifold Mount
Operation Pilot Operated
Pilot Pressure Code None
Response Type Standard Response
Pilot Valve Type CETOP 3, High Performance
Pressure [Max] 5000 psi
EN Code None
Electrical Options None
Spool Code 6
Reducer Module Code None
NFPA Size D08
Performance High Performance
Port Restrictor Plug Code None
Port T Pressure Rating 5000 psi
Spool Spring Arrangement Code C
Spool Control Modification Code 2
Port Restrictor Plugs None
Spool Indicator Switch Code None
Pressure Port Check Valve Pressure N/A
AC/DC AC
Overrides Plain Override Solenoid Ends
Pressure Port Check Valve Code None
Valve Type Standard-Duty
Manual Override Option Code None
Seal Material Buna-N
Reducer Module No
Pilot Valve Type Code H
Electrical Options Code None
Electrical Connector Code None
Function 3-Position Spring Centered
Temperature Range [Max] 230 °F
Tank Port Rating 5000
Center Position P Blocked, A & B to T
Actuation Identification Solenoid A, Solenoid B
Mechanical Options Adjust Pilot Chokes on Both Ends
Gauge Port SAE-4
Coil Rating Code B
Crossover P Blocked, A or B to T
Pilot Drain Code T
Manual Override Plain Override
Design No. 10
Fluid Cleanliness 19/17/14 micron
No. of Stages Two Stage
Solenoid Double
Leakage High Performance
Response Type Code None
Body Material Ductile Iron
Model No. DG5V-8-H-6C-2-T-M-FW-B-10
Indicator Lights No
Coil Type Code F
Mechanical Options Code None
Surge Suppressor/Damper None
Electrical Connection No Connector
Voltage & Frequency 110/120 VAC - 50/60 Hz
Actuator Type Solenoid
Rated Flow [Max] 175 gal/min
Gauge Ports Code None
Solenoid Indicator Lights Code None
Housing Code W
Weight 35.0 LB