- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Spool Code | 6 |
| Manual Override Option Code | None |
| Surge Suppressor/Damper | None |
| Response Type | Standard Response |
| Tank Port Rating | 5000 |
| Temperature Range [Min] | -40 °F |
| Body Material | Ductile Iron |
| NFPA Size | D08 |
| Port Restrictor Plugs | None |
| Manual Override | Plain Override |
| Pilot Valve Type Code | H |
| EN Code | None |
| Mechanical Options Code | None |
| Model No. | DG5V-8-H-6C-2-T-M-FW-B-10 |
| Actuation Identification | Solenoid A, Solenoid B |
| AC/DC | AC |
| Operation | Pilot Operated |
| Reducer Module Code | None |
| Performance | High Performance |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Electrical Options | None |
| Overrides | Plain Override Solenoid Ends |
| Spool Indicator Switch Code | None |
| Electrical Options Code | None |
| Solenoid Energization Code | None |
| Mechanical Options | Adjust Pilot Chokes on Both Ends |
| Crossover | P Blocked, A or B to T |
| Housing Code | W |
| Spool Spring Arrangement Code | C |
| Electrical Connector Code | None |
| Coil Type Code | F |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Surge Suppressor/Damper Code | None |
| Reducer Module | No |
| Electrical Connection | No Connector |
| Pressure Port Check Valve Pressure | N/A |
| Gauge Ports Code | None |
| Pilot Pressure Code | None |
| No. of Stages | Two Stage |
| Valve Type | Standard-Duty |
| Center Position | P Blocked, A & B to T |
| Temperature Range [Max] | 230 °F |
| Gauge Port | SAE-4 |
| Pilot Drain Code | T |
| Pressure Port Check Valve Code | None |
| Leakage | High Performance |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Pilot/Drain | Internal Pilot/Internal Drain |
| Rated Flow [Max] | 175 gal/min |
| Design No. | 10 |
| Solenoid | Double |
| Port Restrictor Plug Code | None |
| Mounting | Subplate/Manifold Mount |
| Indicator Lights | No |
| Port T Pressure Rating | 5000 psi |
| Coil Rating Code | B |
| Pressure [Max] | 5000 psi |
| Fluid Cleanliness | 19/17/14 micron |
| Actuator Type | Solenoid |
| Function | 3-Position Spring Centered |
| Seal Material | Buna-N |
| Pilot Valve Type | CETOP 3, High Performance |
| Compatible Fluids | Petroleum Oil |
| Solenoid Indicator Lights Code | None |
| Response Type Code | None |
| Spool Control Modification Code | 2 |
| Weight | 35.0 LB |