Vickers D10 Solenoid Valve
Item #102018796
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-393331
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Pressure Port Check Valve Pressure N/A
Pilot Pressure [Max] 3000 psi
No. of Stages Two Stage
Pilot/Drain Internal Drain
Coil Type Code U
Fluid Cleanliness 19/17/14 micron
Port Restrictor Plug Code None
Actuation Identification Solenoid A, Solenoid B
Electrical Connection No Connector
Seal Material Buna-N
NFPA Size D10
Indicator Lights No
Mechanical Options None
EN Code None
Model No. DG5V-10-S-2C-E-T-M-U-B-10
Housing Code None
Surge Suppressor/Damper Code None
Compatible Fluids Petroleum Oil
Solenoid Energization Code None
Solenoid Indicator Lights Code None
Pressure Port Check Valve Code None
Manual Override Plain Override
Pressure [Max] 5000 psi
Operation Solenoid Operated
Electrical Connector Code None
Body Material Ductile Iron
Pilot Valve Type Code S
Electrical Options Code None
Response Type Code None
Coil Type ISO 4400
Crossover All Ports Blocked
Tank Port Rating 3000
Rated Flow [Max] 175 gal/min
Manual Override Option Code None
Pilot Valve Type CETOP 3, Standard Performance
Assembly Code None
Reducer Module Code None
Leakage Standard Performance
Electrical Options None
Port Restrictor Plugs None
Temperature Range [Min] -0.4 °F
Coil Rating Code B
AC/DC AC
Voltage & Frequency 110/120 VAC - 50/60 Hz
Function 3-Position Spring Centered
Gauge Ports Code None
Spool Code 2
Spool Control Modification Code None
Actuator Type Solenoid
Temperature Range [Max] 150.8 °F
Valve Type Standard-Duty
Spool Spring Arrangement Code C
Pilot Pressure Code E
Surge Suppressor/Damper None
Overrides Plain Override Solenoid Ends
Pilot Drain Code T
Port T Pressure Rating 3000 psi
Mounting Subplate/Manifold Mount
Gauge Port SAE-4
Design No. 10
Reducer Module N/A
Center Position All Ports Blocked
Solenoid Double
Response Type Standard Response
Weight 100.0 LB