Vickers D05 Solenoid Valve
Item #101996179
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-391847
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D05 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • Series 02 two-stage directional valves are designed to meet the requirements of high performance, precision industrial hydraulic systems operating at pressure to 210 bar (3,000 psi) and flows to 130 l/min (34 U.S. gpm), depending on spool type.

features

  • Quiet, long-life solenoids can be quickly replaced without disturbing the hydraulic circuitry for easy maintenance
  • Tapered main spool lands which permit faster operation with less hydraulic shock
  • Advanced design pilot valves provide reduced power consumption without any sacrifice of valve performance
EN Code None
Reducer Module N/A
Design No. 30
Housing Code W
Actuation Identification Solenoid A, Solenoid B
AC/DC AC
Pilot Valve Type N/A
Spool Spring Arrangement Code C
Operation Solenoid Operated
Surge Suppressor/Damper None
Mounting Subplate/Manifold Mount
Pilot Pressure [Max] 3000 psi
Pilot Valve Tank Pressure Rating Code 6
Electrical Connection No Connector
Body Material Gray Iron
Fluid Cleanliness 19/17/14 micron
Temperature Range [Min] -0.4 °F
Assembly Code None
Mounting Screw Option Code None
Electrical Options Code None
Coil Rating Code B
Spool Code 8
Manual Override Option Code None
Spool Indicator Switch Code None
Temperature Range [Max] 150.8 °F
Electrical Connector Code None
Crossover All Ports Open, Restricted
Function 3-Position Spring Centered
Pilot/Drain External Drain
Response Type Standard Response
Actuator Type Solenoid
Pressure Port Check Valve Pressure N/A
Valve Type Standard-Duty
Solenoid Double
Mechanical Options None
Seal Material Buna-N
No. of Stages Two Stage
Indicator Lights No
Port Restrictor Plug Code None
Pilot Drain Code None
Rated Flow [Max] 30 gal/min
Overrides Plain Override Solenoid Ends
Port T Pressure Rating 2285 psi
Model No. DG5S4-02-8C-VM-FW-B6-30
Pilot Pressure Code None
NFPA Size D05
Center Position P to T, A & B Blocked
Leakage Standard Performance
Manual Override Plain Override
Pressure [Max] 3000 psi
Coil Type 1/2 in NPT Thread Wiring Housing
Solenoid Indicator Lights Code None
Spool Control Modification Code None
Response Type Code None
Pilot Pressure [Min] 75 psi
Electrical Options None
Pressure Port Check Valve Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Tank Port Rating 2321
Port Restrictor Plugs None
Coil Type Code F
Solenoid Energization Code V
Weight 13.0 LB