Vickers by Danfoss02-391226

02-391226

Vickers D08 Solenoid Valve
Item #101907446
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-391226
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Design No. 10
Function 3-Position Spring Centered
Crossover P Blocked, A or B to T
Center Position P Blocked, A & B to T
Surge Suppressor/Damper Code None
Seal Material Buna-N
EN Code None
Pilot Drain Code None
Electrical Options None
Electrical Connection Wired Terminal Block
Port Restrictor Plugs None
Overrides Plain Override Solenoid Ends
Pilot Valve Type Code S
Response Type Code X
Gauge Port SAE-4
Tank Port Rating 5000
Port T Pressure Rating 5000 psi
Spool Control Modification Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Coil Rating Code B
Spool Code 6
Housing Code W
Port Restrictor Plug Code None
Mechanical Options Code None
NFPA Size D08
Electrical Connector Code T
Solenoid Energization Code None
Manual Override Option Code None
Reducer Module Code None
Solenoid Indicator Lights Code L
Pilot Pressure Code None
Model No. DG5V-8-S-6C-X-M-FTWL-B-10
Reducer Module N/A
Gauge Ports Code None
Pilot Valve Type CETOP 3, Standard Performance
Rated Flow [Max] 185 gal/min
Pressure [Max] 5000 psi
Pressure Port Check Valve Code None
Surge Suppressor/Damper None
Solenoid Double
Response Type Fast Response
Pilot/Drain External Pilot/Internal Drain
Spool Spring Arrangement Code C
AC/DC AC
Coil Type Code F
Mechanical Options None
Operation Pilot Operated
Indicator Lights Yes
Actuator Type Solenoid
Manual Override Plain Override
Spool Indicator Switch Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Electrical Options Code None
Valve Type Standard-Duty
Pressure Port Check Valve Pressure N/A
Weight 35.0 LB