Vickers by Danfoss02-390707

02-390707

Vickers D08 Solenoid Valve
Item #101910076
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-390707
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Design allows for possible axial shifting of components relative to the shaft, so utilize this device where exact positioning is not critical
Mounting Subplate/Manifold Mount
Pilot Pressure Code None
Compatible Fluids Petroleum Oil
Gauge Ports Code None
Port T Pressure Rating 5000 psi
Manual Override Option Code None
Reducer Module No
Temperature Range [Min] -40 °F
Manual Override Plain Override
NFPA Size D08
Reducer Module Code None
Overrides Plain Override Solenoid Ends
Pilot Drain Code None
Electrical Options Code None
Solenoid Energization Code None
Center Position P Blocked, A & B to T
Pressure Port Check Valve Pressure N/A
Tank Port Rating 5000
Spool Indicator Switch Code None
Mechanical Options Adjust Pilot Chokes on Both Ends
Body Material Ductile Iron
Leakage High Performance
Coil Rating Code H
Watt Rating 30 W
Coil Type Code U
Seal Material Buna-N
Electrical Options None
Response Type Code None
Surge Suppressor/Damper None
Actuation Identification Solenoid A, Solenoid B
Function 3-Position Spring Centered
Gauge Port SAE-4
Pilot Valve Type CETOP 3, High Performance
Pilot Valve Type Code H
Pressure [Max] 5000 psi
Surge Suppressor/Damper Code None
Indicator Lights No
Electrical Connector Code None
Actuator Type Solenoid
Spool Code 6
Coil Type ISO 4400 (Din 43650) Connector
Operation Pilot Operated
Pilot/Drain Internal Pilot/External Drain
Port Restrictor Plug Code None
Solenoid Indicator Lights Code None
Solenoid Double
Voltage & Frequency 24 VDC
Port Restrictor Plugs None
Pressure Port Check Valve Code None
Valve Type Standard-Duty
Performance High Performance
Electrical Connection No Connector
Crossover P Blocked, A or B to T
Mechanical Options Code None
EN Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
No. of Stages Two Stage
Fluid Cleanliness 19/17/14 micron
Housing Code None
Model No. DG5V-8-H-6C-2-M-U-H-10
Spool Control Modification Code 2
Spool Spring Arrangement Code C
Rated Flow [Max] 175 gal/min
Response Type Standard Response
AC/DC DC
Temperature Range [Max] 230 °F
Design No. 10
Weight 35.0 LB