- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Electrical Connector Code | None |
| Housing Code | None |
| Pilot Valve Type Code | H |
| Center Position | P Blocked, A & B to T |
| Indicator Lights | No |
| Electrical Options Code | None |
| Actuator Type | Solenoid |
| Fluid Cleanliness | 19/17/14 micron |
| Manual Override Option Code | None |
| Spool Spring Arrangement Code | C |
| Reducer Module Code | None |
| Electrical Options | None |
| Design No. | 10 |
| Spool Control Modification Code | None |
| Body Material | Ductile Iron |
| Port T Pressure Rating | 5000 psi |
| Surge Suppressor/Damper Code | None |
| Overrides | Plain Override Solenoid Ends |
| Crossover | P Blocked, A or B to T |
| Pressure [Max] | 5000 psi |
| Model No. | DG5V-8-H-6C-T-M-U-B-10 |
| Pilot Pressure Code | None |
| Surge Suppressor/Damper | None |
| Gauge Ports Code | None |
| Mechanical Options | None |
| Spool Indicator Switch Code | None |
| Reducer Module | No |
| Port Restrictor Plugs | None |
| Response Type | Standard Response |
| Coil Type Code | U |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Pilot Drain Code | T |
| Gauge Port | SAE-4 |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Solenoid Energization Code | None |
| Coil Rating Code | B |
| Performance | High Performance |
| Coil Type | ISO 4400 (Din 43650) Connector |
| Solenoid Indicator Lights Code | None |
| Tank Port Rating | 5000 |
| Spool Code | 6 |
| Pilot Valve Type | CETOP 3, High Performance |
| Pilot/Drain | External Pilot/Internal Drain |
| Electrical Connection | No Connector |
| AC/DC | AC |
| Temperature Range [Min] | -40 °F |
| Pressure Port Check Valve Code | None |
| Response Type Code | None |
| Solenoid | Double |
| Operation | Pilot Operated |
| Function | 3-Position Spring Centered |
| Mounting | Subplate/Manifold Mount |
| Manual Override | Plain Override |
| Actuation Identification | Solenoid A, Solenoid B |
| Mechanical Options Code | None |
| Temperature Range [Max] | 230 °F |
| NFPA Size | D08 |
| No. of Stages | Two Stage |
| EN Code | None |
| Port Restrictor Plug Code | None |
| Pressure Port Check Valve Pressure | N/A |
| Compatible Fluids | Petroleum Oil |
| Seal Material | Buna-N |
| Valve Type | Standard-Duty |
| Rated Flow [Max] | 175 gal/min |
| Leakage | High Performance |
| Weight | 35.0 LB |