DG5V-10 Series Pilot Operated Directional Valve
Item #101909322
  • Double Solenoid Pilot Operated Directional Valve
  • 3-Position Spring Centered
  • 24 VDC
  • DIN 43650
  • No Connector
  • Ctr Pos: All Ports Blocked
  • External Pilot / External Drain
  • None
  • Pilot Valve: CETOP 3, Standard Performance
+ Show More + Show Less
Vickers by Danfoss02-364757
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Double Solenoid Pilot Operated Directional Valve
  • 3-Position Spring Centered
  • 24 VDC
  • DIN 43650
  • No Connector

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Pressure [Max] 5000 psi
Operation Pilot Operated
Coil Rating Code H
EN Code None
Gauge Ports Code None
Response Type Code None
Assembly Code None
NFPA Size D10
Actuator Type Solenoid
Valve Type Standard-Duty
Solenoid Indicator Lights Code None
Manual Override Option Code None
Solenoid Energization Code None
Electrical Connector Code None
Pilot Pressure Code E
Spool Control Modification Code None
Surge Suppressor/Damper None
Electrical Options Code 2
Pilot Valve Type CETOP 3, Standard Performance
Port Restrictor Plug Code None
Voltage & Frequency 24 VDC
Solenoid Double
Port Restrictor Plugs None
Response Type Standard Response
Housing Code None
Pressure Port Check Valve Code None
Pilot/Drain External Pilot/External Drain
Design No. 10
Center Position All Ports Blocked
Coil Type Code U
Pilot Pressure [Max] 3000 psi
Pilot Drain Code None
Overrides Plain Override Solenoid Ends
Coil Type DIN 43650
Reducer Module Code None
Spool Code 2
Port T Pressure Rating 3000 psi
AC/DC DC
Rated Flow [Max] 290 gal/min
Spool Spring Arrangement Code C
Mechanical Options None
Seal Material Buna-N
Reducer Module N/A
Electrical Connection No Connector
Indicator Lights No
Pressure Port Check Valve Pressure N/A
Surge Suppressor/Damper Code None
Gauge Port SAE-4
Crossover All Ports Blocked
Pilot Valve Type Code S
Electrical Options w/Fitted Plug & Variable Grommet
Function 3-Position Spring Centered
Weight 100.0 LB