description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Gauge Ports Code None
Solenoid Energization Code None
Gauge Port SAE-4
EN Code None
Body Material Gray Iron
Port T Pressure Rating 5000 psi
Pressure Port Check Valve Pressure N/A
Spool Control Modification Code None
Port Restrictor Plugs None
Housing Code None
Center Position P Blocked, A & B to T
Indicator Lights No
Rated Flow [Max] 175 gal/min
Seal Material Buna-N
Mounting Subplate/Manifold Mount
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Pilot Drain Code None
Surge Suppressor/Damper None
Electrical Connection No Connector
Pilot/Drain External Pilot/Internal Drain
Tank Port Rating 5000
Manual Override Plain Override
Performance High Performance
Manual Override Option Code None
Reducer Module Code None
Spool Indicator Switch Code None
Coil Type Code U
Pilot Pressure Code None
Electrical Connector Code None
Fluid Cleanliness 20/18/15 micron
Valve Type Standard-Duty
Design No. 10
Mechanical Options None
Electrical Options None
Spool Center Condition A Port and Double Offset sensing switch on B Port
AC/DC AC
Function 3-Position Spring Centered
Coil Type ISO 4400 (Din 43650) Connector
Pilot Valve Type Code H
Overrides Plain Override Solenoid Ends
Compatible Fluids Petroleum Oil
Model No. DG5V-8-H-6C-M-U-B-10
Surge Suppressor/Damper Code None
Crossover P Blocked, A or B to T
Reducer Module No
Pressure [Max] 5000 psi
Voltage & Frequency 110/120 VAC - 50/60 Hz
Operation Pilot Operated
Response Type Standard Response
Pilot Valve Type CETOP 3, High Performance
Solenoid Indicator Lights Code None
Spool Spring Arrangement Code C
Solenoid Double
Response Type Code None
Spool Code 6
No. of Stages Two Stage
Leakage Standard Performance
Mechanical Options Code None
Electrical Options Code None
Actuator Type Solenoid
NFPA Size D08
Coil Rating Code B
Port Restrictor Plug Code None
Pressure Port Check Valve Code None
Weight 35.0 LB