Vickers by Danfoss02-364038

02-364038

DG5V-10 Series Pilot Operated Directional Valve
Item #101907777
  • Double Solenoid Pilot Operated Directional Valve
  • 3-Position Detented
  • 110 VAC - 50 Hz
  • DIN 43650
  • No Connector
  • Ctr Pos: All Ports Blocked
  • External Pilot / External Drain
  • None
  • Pilot Valve: CETOP 3, High Performance
+ Show More + Show Less
Vickers by Danfoss02-364038
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Double Solenoid Pilot Operated Directional Valve
  • 3-Position Detented
  • 110 VAC - 50 Hz
  • DIN 43650
  • No Connector

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Electrical Options Code None
Reducer Module N/A
Pilot Valve Type Code H
EN Code None
Solenoid Energization Code None
Response Type Standard Response
Spool Code 2
Reducer Module Code None
Valve Type Standard-Duty
Pilot Valve Type CETOP 3, High Performance
Response Type Code None
Function 3-Position Detented
Pilot/Drain External Pilot/External Drain
Coil Type Code U
Assembly Code None
Operation Pilot Operated
Overrides Plain Override Solenoid Ends
Pressure Port Check Valve Code K
Coil Type DIN 43650
AC/DC AC
Gauge Port SAE-4
Port T Pressure Rating 3000 psi
NFPA Size D10
Housing Code None
Electrical Options None
Coil Rating Code A
Spool Control Modification Code None
Pilot Pressure Code E
Port Restrictor Plugs None
Pilot Drain Code None
Design No. 10
Crossover All Ports Blocked
Pressure [Max] 5000 psi
Port Restrictor Plug Code None
Electrical Connection No Connector
Gauge Ports Code None
Voltage & Frequency 110 VAC – 50 Hz
Actuator Type Solenoid
Rated Flow [Max] 290 gal/min
Pressure Port Check Valve Pressure 5 psi
Electrical Connector Code None
Solenoid Indicator Lights Code None
Pilot Pressure [Max] 3000 psi
Indicator Lights No
Surge Suppressor/Damper Code None
Seal Material Buna-N
Manual Override Option Code None
Surge Suppressor/Damper None
Mechanical Options None
Spool Spring Arrangement Code N
Center Position All Ports Blocked
Solenoid Double
Weight 100.0 LB