Vickers by Danfoss02-362388

02-362388

Vickers D08 Solenoid Valve
Item #101908740
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function
Vickers by Danfoss02-362388
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Detented Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Tank Port Rating 5000
Pressure Port Check Valve Code None
Electrical Options None
Seal Material Buna-N
Reducer Module N/A
Pilot Drain Code T
Response Type Code None
Center Position All Ports Blocked
Design No. 10
Pilot/Drain External Pilot/Internal Drain
Operation Pilot Operated
Crossover All Ports Blocked
Coil Rating Code B
Spool Control Modification Code 2
Pressure Port Check Valve Pressure N/A
Manual Override Plain Override
Surge Suppressor/Damper Code None
Valve Type Standard-Duty
NFPA Size D08
Gauge Port SAE-4
Mechanical Options Adjust Pilot Chokes on Both Ends
Electrical Options Code None
Actuator Type Solenoid
Model No. DG5V-8-H-2N-2-T-M-U-B-10
Solenoid Indicator Lights Code None
Spool Code 2
Mechanical Options Code None
Pilot Valve Type Code H
Surge Suppressor/Damper None
Electrical Connector Code None
Electrical Connection No Connector
Function 3-Position Detented
Port Restrictor Plugs None
Coil Type DIN 43650
Gauge Ports Code None
Port Restrictor Plug Code None
Spool Spring Arrangement Code N
Indicator Lights No
Solenoid Energization Code None
Pilot Valve Type CETOP 3, High Performance
AC/DC AC
Port T Pressure Rating 5000 psi
Rated Flow [Max] 185 gal/min
Pressure [Max] 5000 psi
Pilot Pressure Code None
Spool Indicator Switch Code None
Housing Code None
Coil Type Code U
Reducer Module Code None
Solenoid Double
Response Type Standard Response
Voltage & Frequency 110/120 VAC - 50/60 Hz
Overrides Plain Override Solenoid Ends
EN Code None
Manual Override Option Code None
Weight 35.0 LB