Vickers by Danfoss02-357914

02-357914

Vickers D10 Solenoid Valve
Item #101906634
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-357914
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Spool Control Modification Code 3
Solenoid Double
Assembly Code None
Overrides Plain Override Solenoid Ends
Pilot Valve Type Code H
Pilot Drain Code None
EN Code None
AC/DC DC
Operation Pilot Operated
Electrical Options Code None
Design No. 10
Coil Rating Code H
Valve Type Standard-Duty
Response Type Standard Response
Spool Spring Arrangement Code C
Coil Type DIN 43650
Pressure [Max] 5000 psi
Function 3-Position Spring Centered
Reducer Module Code None
Housing Code None
Port Restrictor Plugs None
Electrical Options None
Model No. DG5V-10-H-3C-3-M-U-H-10
Solenoid Energization Code None
Surge Suppressor/Damper None
Port Restrictor Plug Code None
Pressure Port Check Valve Code None
Gauge Ports Code None
Surge Suppressor/Damper Code None
Seal Material Buna-N
Electrical Connector Code None
Pilot Pressure [Max] 3000 psi
NFPA Size D10
Tank Port Rating 3000
Pilot/Drain External Pilot/Internal Drain
Coil Type Code U
Pilot Valve Type CETOP 3, High Performance
Solenoid Indicator Lights Code None
Pressure Port Check Valve Pressure N/A
Voltage & Frequency 24 VDC
Reducer Module N/A
Center Position P & B Blocked, A to T
Crossover All Ports Blocked, or P & B Blocked, A to T
Response Type Code None
Electrical Connection No Connector
Gauge Port SAE-4
Manual Override Plain Override
Spool Code 3
Rated Flow [Max] 290 gal/min
Manual Override Option Code None
Mechanical Options Adjust Pilot Chokes on Both Ends, Adjust Stroke on Both Ends
Indicator Lights No
Actuator Type Solenoid
Port T Pressure Rating 3000 psi
Pilot Pressure Code None
Weight 100.0 LB