Vickers by Danfoss02-356816

02-356816

Vickers D10 Solenoid Valve
Item #101907267
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-356816
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Pilot Pressure Code E
Port Restrictor Plug Code None
AC/DC AC
Housing Code None
Spool Code 6
Port T Pressure Rating 3000 psi
Overrides Plain Override Solenoid Ends
Electrical Connector Code None
Valve Type Standard-Duty
Solenoid Double
Pressure Port Check Valve Code None
Crossover P Blocked, A or B to T
Operation Pilot Operated
Model No. DG5V-10-S-6C-E-T-M-U-B-10
Solenoid Indicator Lights Code None
Function 3-Position Spring Centered
Port Restrictor Plugs None
Center Position P Blocked, A & B to T
Pressure [Max] 5000 psi
Gauge Ports Code None
Solenoid Energization Code None
Pilot Pressure [Max] 3000 psi
Actuator Type Solenoid
Design No. 10
Manual Override Option Code None
Pilot Drain Code T
Indicator Lights No
Rated Flow [Max] 290 gal/min
Manual Override Plain Override
Tank Port Rating 3000
Reducer Module N/A
Assembly Code None
EN Code None
Electrical Options None
Pressure Port Check Valve Pressure N/A
Reducer Module Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Mechanical Options None
Pilot/Drain External Pilot/Internal Drain
Electrical Connection No Connector
Pilot Valve Type CETOP 3, Standard Performance
Seal Material Buna-N
Coil Type Code U
Surge Suppressor/Damper None
Electrical Options Code None
Spool Spring Arrangement Code C
NFPA Size D10
Surge Suppressor/Damper Code None
Spool Control Modification Code None
Pilot Valve Type Code S
Coil Rating Code B
Coil Type DIN 43650
Response Type Code None
Response Type Standard Response
Gauge Port SAE-4
Weight 100.0 LB