Skip to content Skip to navigation menu
Vickers by Danfoss02-356635

02-356635

Vickers D10 Solenoid Valve
Item #101907270
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-356635
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Mechanical Options Adjust Pilot Chokes on Both Ends, Adjust Stroke on Both Ends
Response Type Standard Response
Pilot Valve Type Code H
Valve Type Standard-Duty
Electrical Connection No Connector
Tank Port Rating 3000
Solenoid Double
Overrides Plain Override Solenoid Ends
Actuator Type Solenoid
Solenoid Indicator Lights Code None
Solenoid Energization Code None
Reducer Module Code None
Response Type Code None
Pilot/Drain External Pilot/Internal Drain
Electrical Connector Code None
Pressure Port Check Valve Code None
Surge Suppressor/Damper None
Reducer Module N/A
Electrical Options None
Center Position All Ports Blocked
Rated Flow [Max] 290 gal/min
Function 3-Position Spring Centered
Coil Type DIN 43650
Pilot Valve Type CETOP 3, High Performance
Spool Spring Arrangement Code C
Spool Code 2
Port Restrictor Plug Code None
Seal Material Buna-N
Spool Control Modification Code 3
Pilot Drain Code None
Manual Override Option Code None
Crossover All Ports Blocked
Indicator Lights No
Coil Type Code U
Port Restrictor Plugs None
Housing Code None
AC/DC DC
Model No. DG5V-10-H-2C-3-M-U-H-10
Gauge Ports Code None
NFPA Size D10
Pressure [Max] 5000 psi
Pressure Port Check Valve Pressure N/A
Pilot Pressure Code None
Port T Pressure Rating 3000 psi
Design No. 10
Operation Pilot Operated
EN Code None
Voltage & Frequency 24 VDC
Pilot Pressure [Max] 3000 psi
Manual Override Plain Override
Electrical Options Code None
Coil Rating Code H
Surge Suppressor/Damper Code None
Assembly Code None
Gauge Port SAE-4
Weight 100.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison