Vickers D10 Solenoid Valve
Item #101907270
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-356635
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Assembly Code None
Electrical Connection No Connector
Surge Suppressor/Damper None
Mechanical Options Adjust Pilot Chokes on Both Ends, Adjust Stroke on Both Ends
Reducer Module Code None
Pilot Valve Type CETOP 3, High Performance
Electrical Options Code None
Pressure [Max] 5000 psi
Pilot Drain Code None
Model No. DG5V-10-H-2C-3-M-U-H-10
EN Code None
NFPA Size D10
Indicator Lights No
Spool Spring Arrangement Code C
Actuator Type Solenoid
Crossover All Ports Blocked
Valve Type Standard-Duty
Pressure Port Check Valve Pressure N/A
Function 3-Position Spring Centered
Center Position All Ports Blocked
AC/DC DC
Surge Suppressor/Damper Code None
Pilot Pressure Code None
Coil Rating Code H
Operation Pilot Operated
Port T Pressure Rating 3000 psi
Manual Override Plain Override
Electrical Options None
Solenoid Double
Gauge Port SAE-4
Manual Override Option Code None
Voltage & Frequency 24 VDC
Solenoid Energization Code None
Coil Type DIN 43650
Seal Material Buna-N
Tank Port Rating 3000
Design No. 10
Response Type Code None
Pilot Valve Type Code H
Housing Code None
Overrides Plain Override Solenoid Ends
Electrical Connector Code None
Solenoid Indicator Lights Code None
Spool Control Modification Code 3
Reducer Module N/A
Port Restrictor Plug Code None
Spool Code 2
Coil Type Code U
Gauge Ports Code None
Rated Flow [Max] 290 gal/min
Port Restrictor Plugs None
Pressure Port Check Valve Code None
Pilot/Drain External Pilot/Internal Drain
Response Type Standard Response
Pilot Pressure [Max] 3000 psi
Weight 100.0 LB