Vickers by Danfoss02-356502

02-356502

Vickers D08 Solenoid Valve
Item #101908958
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function
Vickers by Danfoss02-356502
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Manual Override Option Code None
Pressure [Max] 5000 psi
Port T Pressure Rating 5000 psi
Pressure Port Check Valve Pressure N/A
Coil Rating Code B
Surge Suppressor/Damper Code None
Reducer Module Code None
Tank Port Rating 5000
Valve Type Standard-Duty
Indicator Lights No
Pilot/Drain External Pilot/Internal Drain
Mechanical Options None
Solenoid Indicator Lights Code None
Pilot Valve Type Code S
Operation Pilot Operated
Coil Type DIN 43650
Overrides Plain Override Solenoid Ends
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port Restrictor Plugs None
Center Position All Ports Open
Port Restrictor Plug Code None
Spool Indicator Switch Code None
Housing Code None
Actuator Type Solenoid
Coil Type Code U
EN Code None
Pilot Pressure Code None
Response Type Standard Response
Spool Spring Arrangement Code A
Gauge Port SAE-4
NFPA Size D08
Reducer Module N/A
Function 2-Position Spring Offset
Response Type Code None
Rated Flow [Max] 185 gal/min
Pressure Port Check Valve Code None
Seal Material Buna-N
Spool Code 0
Electrical Options Code None
Manual Override Plain Override
Pilot Valve Type CETOP 3, Standard Performance
Mechanical Options Code None
Electrical Connector Code None
Gauge Ports Code None
Crossover All Ports Open
Solenoid Single
Model No. DG5V-8-S-0A-M-U-B-10
AC/DC AC
Pilot Drain Code None
Spool Control Modification Code None
Design No. 10
Surge Suppressor/Damper None
Electrical Options None
Electrical Connection No Connector
Solenoid Energization Code None
Weight 35.0 LB