- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| No. of Stages | Two Stage |
| Tank Port Rating | 5000 |
| Spool Spring Arrangement Code | C |
| Reducer Module Code | None |
| Design No. | 10 |
| Electrical Connector Code | None |
| Response Type | Standard Response |
| Rated Flow [Max] | 175 gal/min |
| Coil Type | ISO 4400 (Din 43650) Connector |
| Gauge Port | SAE-4 |
| Coil Rating Code | H |
| Mechanical Options | None |
| Surge Suppressor/Damper Code | None |
| Seal Material | Buna-N |
| Valve Type | Standard-Duty |
| Spool Control Modification Code | None |
| Solenoid | Double |
| Gauge Ports Code | None |
| Port Restrictor Plug Code | None |
| Pilot/Drain | Internal Pilot/Internal Drain |
| Coil Type Code | U |
| Response Type Code | None |
| AC/DC | DC |
| Electrical Options Code | None |
| Electrical Options | None |
| Solenoid Energization Code | None |
| Mechanical Options Code | None |
| EN Code | None |
| Pressure Port Check Valve Pressure | N/A |
| Crossover | All Ports Blocked, or P & B Blocked, A to T |
| Pilot Drain Code | T |
| Port Restrictor Plugs | None |
| Temperature Range [Min] | -40 °F |
| Manual Override | Plain Override |
| Pilot Valve Type | CETOP 3, High Performance |
| Performance | High Performance |
| Pressure Port Check Valve Code | None |
| Actuator Type | Solenoid |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Spool Code | 3 |
| Spool Indicator Switch Code | None |
| Compatible Fluids | Petroleum Oil |
| Voltage & Frequency | 24 VDC |
| Operation | Pilot Operated |
| Pilot Pressure Code | None |
| Housing Code | None |
| Mounting | Subplate/Manifold Mount |
| Leakage | High Performance |
| Body Material | Ductile Iron |
| Temperature Range [Max] | 230 °F |
| Solenoid Indicator Lights Code | None |
| Pilot Valve Type Code | H |
| Overrides | Plain Override Solenoid Ends |
| Center Position | P & B Blocked, A to T |
| Pressure [Max] | 5000 psi |
| Watt Rating | 30 W |
| Model No. | DG5V-8-H-3C-T-M-U-H-10 |
| Electrical Connection | No Connector |
| Actuation Identification | Solenoid A, Solenoid B |
| Manual Override Option Code | None |
| Fluid Cleanliness | 19/17/14 micron |
| NFPA Size | D08 |
| Reducer Module | No |
| Surge Suppressor/Damper | None |
| Function | 3-Position Spring Centered |
| Indicator Lights | No |
| Port T Pressure Rating | 5000 psi |
| Weight | 35.0 LB |