Vickers by Danfoss02-356215

02-356215

Vickers D10 Solenoid Valve
Item #101911270
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-356215
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Spool Control Modification Code None
Function 3-Position Spring Centered
Mechanical Options None
Assembly Code None
Spool Code 33
Housing Code None
Solenoid Energization Code None
Response Type Code None
Overrides Plain Override Solenoid Ends
Gauge Ports Code None
Model No. DG5V-10-H-33C-M-U-H-10
Voltage & Frequency 24 VDC
Coil Rating Code H
Gauge Port SAE-4
Design No. 10
Seal Material Buna-N
Reducer Module Code None
Indicator Lights No
Port T Pressure Rating 3000 psi
Electrical Options Code None
EN Code None
Solenoid Double
Coil Type DIN 43650
Manual Override Option Code None
Pressure Port Check Valve Pressure N/A
Valve Type Standard-Duty
Actuator Type Solenoid
Coil Type Code U
Reducer Module N/A
Port Restrictor Plugs None
Crossover P Blocked, A or B to T
Pressure [Max] 5000 psi
Pilot/Drain Internal Pilot/External Drain
Electrical Options None
Electrical Connection No Connector
Center Position P Blocked, A & B to T
Operation Pilot Operated
Response Type Standard Response
Solenoid Indicator Lights Code None
Pilot Pressure Code None
Pilot Drain Code None
Tank Port Rating 3000
Pilot Valve Type Code H
Rated Flow [Max] 290 gal/min
NFPA Size D10
Pilot Valve Type CETOP 3, High Performance
Manual Override Plain Override
Pilot Pressure [Max] 3000 psi
Surge Suppressor/Damper Code None
AC/DC DC
Spool Spring Arrangement Code C
Surge Suppressor/Damper None
Electrical Connector Code None
Port Restrictor Plug Code None
Pressure Port Check Valve Code None
Weight 100.0 LB
We're here for you
with Service Centers across the country -
We have your back