- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Port Restrictor Plugs | None |
| Solenoid | Double |
| Electrical Connector Code | T |
| AC/DC | AC |
| Port T Pressure Rating | 5000 psi |
| Tank Port Rating | 5000 |
| Coil Type Code | F |
| Overrides | Plain Override Solenoid Ends |
| NFPA Size | D08 |
| Mechanical Options | None |
| Crossover | P Blocked, A or B to T |
| Response Type Code | None |
| Seal Material | Buna-N |
| Pressure [Max] | 5000 psi |
| Pilot Valve Type Code | S |
| Spool Code | 6 |
| Operation | Pilot Operated |
| Spool Indicator Switch Code | None |
| Pressure Port Check Valve Code | K |
| Surge Suppressor/Damper Code | None |
| Spool Spring Arrangement Code | C |
| Indicator Lights | Yes |
| Gauge Ports Code | None |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Surge Suppressor/Damper | None |
| Manual Override | Plain Override |
| Mounting | Subplate/Manifold Mount |
| Reducer Module | No |
| No. of Stages | Two Stage |
| Center Position | P Blocked, A & B to T |
| Electrical Options Code | None |
| Response Type | Standard Response |
| Mechanical Options Code | None |
| Actuation Identification | Solenoid A, Solenoid B |
| Gauge Port | SAE-4 |
| Design No. | 10 |
| Pilot/Drain | Internal Pilot/External Drain |
| Temperature Range [Min] | -40 °F |
| Pilot Pressure Code | None |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Function | 3-Position Spring Centered |
| Fluid Cleanliness | 19/17/14 micron |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Temperature Range [Max] | 230 °F |
| Pressure Port Check Valve Pressure | 5 psi |
| Valve Type | Standard-Duty |
| Electrical Connection | Wired Terminal Block |
| Port Restrictor Plug Code | None |
| Housing Code | W |
| Pilot Drain Code | None |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Electrical Options | None |
| Solenoid Indicator Lights Code | L |
| Manual Override Option Code | None |
| Solenoid Energization Code | None |
| Coil Rating Code | B |
| Rated Flow [Max] | 175 gal/min |
| Model No. | DG5V-8-S-6C-K-M-FTWL-B-10 |
| Actuator Type | Solenoid |
| Reducer Module Code | None |
| Body Material | Ductile Iron |
| EN Code | None |
| Leakage | Standard Performance |
| Spool Control Modification Code | None |
| Performance | Standard Performance |
| Compatible Fluids | Petroleum Oil |
| Weight | 35.0 LB |