Vickers D03 Solenoid Valve

02-354348

Vickers D03 Solenoid Valve
Item #101924247
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Single Solenoid
  • 2-Position Spring Offset, Left Hand Build Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Up to 21 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
Solenoid Code B
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Voltage & Frequency 110/120 VAC - 50/60 Hz
Indicator Lights Yes
Port T Code 6
Pilot/Drain None
Pressure Port Check Valve Pressure N/A
Leakage Standard Performance
No. of Stages Single Stage
Reducer Module No
Spool Shift Timing N/A
Mounting Subplate/Manifold Mount
Seal Material Buna-N
Spool Indicator Switch Code None
Actuator Type Solenoid
Design No. 60
Spool Spring Arrangement Code A
Surge Suppressor/Damper Code None
Performance High Performance
Electrical Connector Code T
Housing Code W
NFPA Size D03
Mechanical Options None
Pilot Valve Type N/A
Temperature Range [Min] -4 °F
Cycle Rate [Max] N/A
Port Restrictor Plug Code None
Manual Override Option Code None
Model No. DG4V-3-0AL-M-FTWL-B6-60
Overrides No Overrides
Manual Override Plain Override
Electrical Connection Wired Terminal Block
Response Type Standard Response
Spool Code 0
Function Code 0
Port T Pressure Rating 3000 psi
Pressure [Max] 5000 psi
Response Time 15 to 23 ms
Tank Port Rating 3046
Temperature Range [Max] 158 °F
Operation Solenoid Operated
Body Material Gray Iron
Solenoid Energization Code None
Valve Type High-Performance
Center Position All Ports Open
Coil Rating Code B
Solenoid Single
Crossover All Ports Open
Fluid Cleanliness 19/17/14 micron
Actuation Identification Solenoid A
EN Code None
Port Restrictor Plugs None
Surge Suppressor/Damper None
Electrical Options None
Rated Flow [Max] 20 gal/min
AC/DC AC
Function 2-Position Spring Offset, Left Hand Build
Solenoid Indicator Lights Code L
Coil Type Code F
Compatible Fluids Petroleum Oil
Weight 5.0 LB