Vickers D03 Solenoid Valve

02-350239

Vickers D03 Solenoid Valve
Item #101943142
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. The 60-design series has been specially designed and developed to cover expanded demands in the industry as well as the many traditional uses of the earlier designs.

features

  • Efficient control of greater hydraulic powers without increasing solenoid power consumption
  • Multi-fluid capability without the need to change seals
  • Solenoid coils can be changed quickly and easily without leakage from the hydraulic system
  • Compact, cost-effective system design when used with Vickers SystemStak valves and subplates
  • Up to 10.5 gpm at 5,000 psi
  • Valve mounting face conforms to ISO 4401, size 03, and is compatible with related international standards
Surge Suppressor/Damper Code None
Pilot Valve Type N/A
Surge Suppressor/Damper None
Housing Code W
Crossover All Ports Open
Pressure Port Check Valve Pressure N/A
AC/DC AC
Valve Type Standard-Duty
Electrical Options None
Reducer Module N/A
Port Restrictor Plug Code None
Actuator Type Solenoid
Seal Material Buna-N
Solenoid Energization Code None
Overrides No Overrides
Electrical Connector Code T
NFPA Size D03
Center Position All Ports Open
Model No. DG4V 3S 0C M FTW B5 60
Port T Code 5
Operation Solenoid Operated
Tank Port Rating 1500
Spool Indicator Switch Code None
Cycle Rate [Max] N/A
Spool Code 0
Pilot/Drain None
Solenoid Indicator Lights Code None
Port Restrictor Plugs None
Coil Rating Code B
Voltage & Frequency 110/120 VAC - 50/60 Hz
Indicator Lights No
Solenoid Code B
Rated Flow [Max] 10.5 gal/min
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Function Code 0
Coil Type Code F
EN Code None
Spool Spring Arrangement Code C
Design No. 60
Function 3-Position Spring Centered
Solenoid Double
Port T Pressure Rating 1500 psi
Pressure [Max] 5075 psi
Manual Override Option Code None
Electrical Connection Wired Terminal Block
Mechanical Options None
Response Type Standard Response
Spool Shift Timing N/A
Weight 5.0 LB