Vickers by Danfoss02-344333

02-344333

Vickers D08 Solenoid Valve
Item #102061831
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-344333
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Temperatures not to exceed 170 °F (77 °C)
Manual Override Option Code None
Function 3-Position Spring Centered
Mechanical Options None
Coil Rating Code B
No. of Stages Two Stage
EN Code None
Gauge Ports Code None
Leakage Standard Performance
Indicator Lights No
Model No. DG5V-8-H-2C-T-M-U-B-10
Pilot Pressure Code None
Tank Port Rating 5000
Gauge Port SAE-4
Port Restrictor Plug Code None
Coil Type ISO 4400 (Din 43650) Connector
Spool Control Modification Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Seal Material Buna-N
Performance High Performance
Electrical Connection No Connector
Coil Type Code U
Crossover All Ports Blocked
Valve Type Standard-Duty
Spool Code 2
Design No. 10
Reducer Module No
Spool Spring Arrangement Code C
Port T Pressure Rating 5000 psi
Compatible Fluids Petroleum Oil
AC/DC AC
Actuator Type Solenoid
Mounting Subplate/Manifold Mount
Pressure Port Check Valve Code None
Body Material Gray Iron
Solenoid Indicator Lights Code None
Overrides Plain Override Solenoid Ends
Surge Suppressor/Damper None
NFPA Size D08
Rated Flow [Max] 175 gal/min
Pilot Drain Code T
Spool Center Condition A Port and Double Offset sensing switch on B Port
Pressure [Max] 5000 psi
Surge Suppressor/Damper Code None
Electrical Options Code None
Pilot/Drain External Pilot/Internal Drain
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Response Type Standard Response
Fluid Cleanliness 20/18/15 micron
Electrical Options None
Electrical Connector Code None
Port Restrictor Plugs None
Mechanical Options Code None
Center Position All Ports Blocked
Response Type Code None
Reducer Module Code None
Operation Pilot Operated
Solenoid Energization Code None
Pilot Valve Type Code H
Solenoid Double
Pressure Port Check Valve Pressure N/A
Manual Override Plain Override
Housing Code None
Pilot Valve Type CETOP 3, High Performance
Spool Indicator Switch Code None
Weight 35.0 LB