- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Function | 3-Position Spring Centered |
| NFPA Size | D08 |
| Design No. | 10 |
| Spool Control Modification Code | 2 |
| Crossover | P Blocked, A or B to T |
| Leakage | Standard Performance |
| Response Type Code | None |
| Pressure Port Check Valve Code | None |
| Center Position | P Blocked, A & B to T |
| Temperature Range [Max] | 230 °F |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Pressure [Max] | 5000 psi |
| Fluid Cleanliness | 19/17/14 micron |
| No. of Stages | Two Stage |
| Response Type | Standard Response |
| Mechanical Options Code | None |
| Valve Type | Standard-Duty |
| Performance | Standard Performance |
| Surge Suppressor/Damper Code | None |
| Reducer Module Code | None |
| Solenoid Indicator Lights Code | L |
| Overrides | Plain Override Solenoid Ends |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Port Restrictor Plugs | None |
| Actuator Type | Solenoid |
| Body Material | Ductile Iron |
| Seal Material | Buna-N |
| Electrical Options Code | None |
| AC/DC | AC |
| Mounting | Subplate/Manifold Mount |
| Rated Flow [Max] | 175 gal/min |
| EN Code | None |
| Reducer Module | No |
| Mechanical Options | Adjust Pilot Chokes on Both Ends |
| Tank Port Rating | 5000 |
| Pressure Port Check Valve Pressure | N/A |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Pilot Drain Code | T |
| Manual Override Option Code | None |
| Electrical Connector Code | T |
| Spool Indicator Switch Code | None |
| Operation | Pilot Operated |
| Pilot/Drain | Internal Pilot/Internal Drain |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Housing Code | W |
| Compatible Fluids | Petroleum Oil |
| Port T Pressure Rating | 5000 psi |
| Spool Code | 6 |
| Solenoid | Double |
| Coil Type Code | F |
| Temperature Range [Min] | -40 °F |
| Manual Override | Plain Override |
| Electrical Connection | Wired Terminal Block |
| Gauge Ports Code | None |
| Gauge Port | SAE-4 |
| Indicator Lights | Yes |
| Electrical Options | None |
| Model No. | DG5V-8-S-6C-2-T-M-FTWL-B-10 |
| Spool Spring Arrangement Code | C |
| Port Restrictor Plug Code | None |
| Actuation Identification | Solenoid A, Solenoid B |
| Pilot Valve Type Code | S |
| Surge Suppressor/Damper | None |
| Coil Rating Code | B |
| Solenoid Energization Code | None |
| Pilot Pressure Code | None |
| Weight | 35.0 LB |