Skip to content Skip to navigation menu
Vickers by Danfoss02-344050

02-344050

Vickers D10 Solenoid Valve
Item #102099387
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-344050
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Rated Flow [Max] 290 gal/min
AC/DC DC
Solenoid Energization Code None
Coil Type DIN 43650
Pilot/Drain External Pilot/Internal Drain
Electrical Connector Code None
Coil Type Code U
Surge Suppressor/Damper Code None
Coil Rating Code H
Solenoid Double
Gauge Port SAE-4
Pilot Pressure [Max] 3000 psi
Pressure Port Check Valve Code None
Spool Code 2
Electrical Options None
EN Code None
Gauge Ports Code None
Pilot Valve Type CETOP 3, Standard Performance
Model No. DG5V-10-S-2C-E-M-U-H-10
Mechanical Options None
Response Type Standard Response
Tank Port Rating 3000
Crossover All Ports Blocked
Assembly Code None
Manual Override Plain Override
Actuator Type Solenoid
NFPA Size D10
Operation Pilot Operated
Voltage & Frequency 24 VDC
Manual Override Option Code None
Design No. 10
Valve Type Standard-Duty
Pilot Pressure Code E
Port T Pressure Rating 3000 psi
Electrical Options Code None
Response Type Code None
Pilot Drain Code None
Seal Material Buna-N
Overrides Plain Override Solenoid Ends
Housing Code None
Pressure Port Check Valve Pressure N/A
Reducer Module N/A
Function 3-Position Spring Centered
Spool Control Modification Code None
Port Restrictor Plugs None
Solenoid Indicator Lights Code None
Surge Suppressor/Damper None
Electrical Connection No Connector
Pressure [Max] 5000 psi
Port Restrictor Plug Code None
Spool Spring Arrangement Code C
Pilot Valve Type Code S
Reducer Module Code None
Center Position All Ports Blocked
Indicator Lights No
Weight 100.0 LB
Close Compare List Open Compare List Toggle

Product Comparison