Skip to content Skip to navigation menu
Vickers by Danfoss02-344016

02-344016

Vickers D08 Solenoid Valve
Item #102061832
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-344016
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Temperatures not to exceed 170 °F (77 °C)
Reducer Module Code None
Pressure Port Check Valve Pressure N/A
Reducer Module No
Performance Standard Performance
EN Code None
Response Type Code None
Valve Type Standard-Duty
Compatible Fluids Petroleum Oil
Fluid Cleanliness 19/17/14 micron
Electrical Options Code None
Overrides Plain Override Solenoid Ends
Mechanical Options None
Actuator Type Solenoid
Mounting Subplate/Manifold Mount
Solenoid Energization Code None
Pilot Pressure Code E
Pilot Drain Code None
Leakage Standard Performance
Gauge Ports Code None
Electrical Options None
Temperature Range [Max] 230 °F
Temperature Range [Min] -40 °F
Rated Flow [Max] 175 gal/min
NFPA Size D08
Model No. DG5V-8-S-3C-E-M-FTWL-B-10
Seal Material Buna-N
Gauge Port SAE-4
Solenoid Indicator Lights Code L
Port Restrictor Plugs None
Surge Suppressor/Damper None
Operation Pilot Operated
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Electrical Connection Wired Terminal Block
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Indicator Lights Yes
Tank Port Rating 5000
AC/DC AC
Pilot/Drain External Pilot/External Drain
Body Material Ductile Iron
Response Type Standard Response
Mechanical Options Code None
Spool Spring Arrangement Code C
Coil Type Code F
Solenoid Double
Housing Code W
Center Position P & B Blocked, A to T
Manual Override Option Code None
Coil Rating Code B
Spool Indicator Switch Code None
Spool Control Modification Code None
Spool Code 3
Port Restrictor Plug Code None
Function 3-Position Spring Centered
Pressure Port Check Valve Code None
Pilot Valve Type CETOP 3, Standard Performance
Manual Override Plain Override
No. of Stages Two Stage
Electrical Connector Code T
Port T Pressure Rating 5000 psi
Pressure [Max] 5000 psi
Design No. 10
Pilot Valve Type Code S
Actuation Identification Solenoid A, Solenoid B
Voltage & Frequency 110/120 VAC - 50/60 Hz
Crossover All Ports Blocked, or P & B Blocked, A to T
Surge Suppressor/Damper Code None
Weight 35.0 LB