Skip to content Skip to navigation menu
Vickers by Danfoss02-343555

02-343555

Vickers D08 Solenoid Valve
Item #101889898
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-343555
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Cannot be used in air systems where compressors are lubricated with fire-resistant fluids, such as phosphate ester and di-ester types
Electrical Connection No Connector
Pressure Port Check Valve Pressure N/A
Mechanical Options Code None
No. of Stages Two Stage
Function 3-Position Spring Centered
Model No. DG5V-8-S-9C-E-M-FW-B-10
Pilot/Drain External Pilot/External Drain
Spool Code 9
Response Type Standard Response
Performance Standard Performance
Body Material Ductile Iron
Compatible Fluids Petroleum Oil
Crossover All Ports Open
Coil Rating Code B
Reducer Module No
Temperature Range [Max] 230 °F
EN Code None
Temperature Range [Min] -40 °F
Coil Type Code F
Port Restrictor Plugs None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Seal Material Buna-N
Center Position All Ports Open Over Tapers
Pilot Valve Type CETOP 3, Standard Performance
Mounting Subplate/Manifold Mount
Tank Port Rating 5000
Manual Override Option Code None
Electrical Connector Code None
Electrical Options Code None
Mechanical Options None
Pilot Pressure Code E
Port T Pressure Rating 5000 psi
Solenoid Double
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Pilot Drain Code None
Spool Indicator Switch Code None
Reducer Module Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Fluid Cleanliness 19/17/14 micron
Valve Type Standard-Duty
Spool Control Modification Code None
Housing Code W
Port Restrictor Plug Code None
Design No. 10
Operation Pilot Operated
Pressure [Max] 5000 psi
Gauge Ports Code None
Actuation Identification Solenoid A, Solenoid B
Response Type Code None
Surge Suppressor/Damper None
Rated Flow [Max] 175 gal/min
Gauge Port SAE-4
Pressure Port Check Valve Code None
AC/DC AC
Solenoid Energization Code None
NFPA Size D08
Indicator Lights No
Electrical Options None
Manual Override Plain Override
Leakage Standard Performance
Overrides Plain Override Solenoid Ends
Actuator Type Solenoid
Solenoid Indicator Lights Code None
Spool Spring Arrangement Code C
Pilot Valve Type Code S
Surge Suppressor/Damper Code None
Weight 35.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison