Vickers by Danfoss02-343471

02-343471

Vickers D08 Solenoid Valve
Item #101908907
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-343471
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Manual Override Option Code None
Gauge Port SAE-4
Function 3-Position Spring Centered
Mechanical Options Code None
Overrides Plain Override Solenoid Ends
Actuator Type Solenoid
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Spool Code 2
Spool Indicator Switch Code None
Rated Flow [Max] 185 gal/min
Reducer Module N/A
Electrical Connection No Connector
Indicator Lights No
Manual Override Plain Override
Valve Type Standard-Duty
Coil Type Code F
Pilot Valve Type Code H
Pilot Valve Type CETOP 3, High Performance
Port T Pressure Rating 5000 psi
Port Restrictor Plug Code None
Surge Suppressor/Damper None
Tank Port Rating 5000
Pressure Port Check Valve Pressure 75 psi
Spool Spring Arrangement Code C
Design No. 10
NFPA Size D08
Seal Material Buna-N
Port Restrictor Plugs None
Pilot/Drain External Pilot/Internal Drain
Reducer Module Code None
Electrical Options None
Solenoid Energization Code None
Housing Code W
Solenoid Double
Surge Suppressor/Damper Code None
Crossover All Ports Blocked
Model No. DG5V-8-H-2C-S-M-FW-B-10
Pilot Drain Code None
Mechanical Options None
Gauge Ports Code None
Response Type Standard Response
Center Position All Ports Blocked
Pressure [Max] 5000 psi
Pilot Pressure Code None
Electrical Options Code None
Solenoid Indicator Lights Code None
Coil Rating Code B
AC/DC AC
Operation Pilot Operated
Spool Control Modification Code None
Electrical Connector Code None
EN Code None
Response Type Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Pressure Port Check Valve Code S
Weight 35.0 LB