- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Detented Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| NFPA Size | D08 |
| Pressure Port Check Valve Pressure | N/A |
| No. of Stages | Two Stage |
| Pressure [Max] | 5000 psi |
| Gauge Ports Code | None |
| Electrical Options | None |
| Pilot Drain Code | None |
| Mechanical Options Code | None |
| Spool Code | 2 |
| Leakage | Standard Performance |
| Center Position | All Ports Blocked |
| Performance | Standard Performance |
| Reducer Module Code | None |
| Model No. | DG5V-8-S-2N-2-M-FW-B-10 |
| Port T Pressure Rating | 5000 psi |
| Pilot/Drain | Internal Pilot/External Drain |
| Spool Indicator Switch Code | None |
| Manual Override | Plain Override |
| Port Restrictor Plugs | None |
| Mounting | Subplate/Manifold Mount |
| Solenoid Indicator Lights Code | None |
| Solenoid Energization Code | None |
| Pressure Port Check Valve Code | None |
| AC/DC | AC |
| EN Code | None |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Surge Suppressor/Damper | None |
| Electrical Connection | No Connector |
| Electrical Options Code | None |
| Gauge Port | SAE-4 |
| Port Restrictor Plug Code | None |
| Temperature Range [Max] | 230 °F |
| Overrides | Plain Override Solenoid Ends |
| Seal Material | Buna-N |
| Pilot Valve Type Code | S |
| Response Type | Standard Response |
| Reducer Module | No |
| Pilot Pressure Code | None |
| Compatible Fluids | Petroleum Oil |
| Actuator Type | Solenoid |
| Temperature Range [Min] | -40 °F |
| Coil Type Code | F |
| Manual Override Option Code | None |
| Housing Code | W |
| Crossover | All Ports Blocked |
| Response Type Code | None |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Indicator Lights | No |
| Rated Flow [Max] | 175 gal/min |
| Actuation Identification | Solenoid A, Solenoid B |
| Design No. | 10 |
| Electrical Connector Code | None |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Surge Suppressor/Damper Code | None |
| Body Material | Ductile Iron |
| Operation | Pilot Operated |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Mechanical Options | Adjust Pilot Chokes on Both Ends |
| Fluid Cleanliness | 19/17/14 micron |
| Tank Port Rating | 5000 |
| Solenoid | Double |
| Spool Control Modification Code | 2 |
| Function | 3-Position Detented |
| Spool Spring Arrangement Code | N |
| Coil Rating Code | B |
| Valve Type | Standard-Duty |
| Weight | 35.0 LB |