Skip to content Skip to navigation menu
Vickers by Danfoss02-342106

02-342106

Vickers D08 Solenoid Valve
Item #101909098
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-342106
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Design allows for possible axial shifting of components relative to the shaft, so utilize this device where exact positioning is not critical
Indicator Lights No
NFPA Size D08
Electrical Options None
Pilot Valve Type CETOP 3, High Performance
Body Material Gray Iron
Spool Spring Arrangement Code C
Pilot Valve Type Code H
Manual Override Plain Override
Function 3-Position Spring Centered
AC/DC AC
Spool Center Condition A Port and Double Offset sensing switch on B Port
Electrical Connector Code None
Coil Type Code F
Coil Rating Code B
Voltage & Frequency 110/120 VAC - 50/60 Hz
Solenoid Indicator Lights Code None
Surge Suppressor/Damper Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Mechanical Options Code None
Pressure [Max] 5000 psi
Electrical Connection No Connector
Mechanical Options None
Electrical Options Code None
Response Type Code None
Surge Suppressor/Damper None
EN Code None
Spool Indicator Switch Code None
Compatible Fluids Petroleum Oil
Crossover All Ports Open, Restricted
Pressure Port Check Valve Code None
Reducer Module Code None
Mounting Subplate/Manifold Mount
Pilot Pressure Code E
Leakage Standard Performance
Tank Port Rating 5000
Response Type Standard Response
Center Position P to T, A & B Blocked
Solenoid Energization Code V
Housing Code W
Spool Control Modification Code None
Spool Code 8
Pressure Port Check Valve Pressure N/A
Manual Override Option Code None
Valve Type Standard-Duty
Seal Material Buna-N
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Port T Pressure Rating 5000 psi
Model No. DG5V-8-H-8C-E-VM-FW-B-10
Fluid Cleanliness 19/17/14 micron
Actuator Type Solenoid
Gauge Port SAE-4
Design No. 10
Port Restrictor Plugs None
Solenoid Double
Pilot Drain Code None
Gauge Ports Code None
Port Restrictor Plug Code None
Pilot/Drain External Pilot/Internal Drain
Operation Pilot Operated
Overrides Plain Override Solenoid Ends
No. of Stages Two Stage
Rated Flow [Max] 175 gal/min
Performance High Performance
Reducer Module No
Weight 35.0 LB