Vickers by Danfoss02-339870

02-339870

Vickers D10 Solenoid Valve
Item #101908858
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-339870
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
Design No. 10
Coil Type Code U
Pressure Port Check Valve Code None
AC/DC AC
Seal Material Buna-N
Solenoid Indicator Lights Code None
Electrical Connector Code None
Housing Code None
Valve Type Standard-Duty
Assembly Code None
Tank Port Rating 3000
Crossover All Ports Blocked
Spool Spring Arrangement Code C
Pilot/Drain External Pilot/Internal Drain
Port Restrictor Plugs None
Response Type Standard Response
Indicator Lights No
Port Restrictor Plug Code None
Rated Flow [Max] 290 gal/min
Port T Pressure Rating 3000 psi
Pilot Drain Code None
Manual Override Option Code None
Model No. DG5V-10-S-2C-E-M-U-B-10
Solenoid Double
Electrical Options Code None
Reducer Module N/A
EN Code None
Mechanical Options None
NFPA Size D10
Voltage & Frequency 110/120 VAC - 50/60 Hz
Actuator Type Solenoid
Pilot Valve Type CETOP 3, Standard Performance
Pilot Valve Type Code S
Electrical Connection No Connector
Spool Code 2
Pressure Port Check Valve Pressure N/A
Gauge Ports Code None
Response Type Code None
Coil Type DIN 43650
Pilot Pressure Code E
Spool Control Modification Code None
Gauge Port SAE-4
Solenoid Energization Code None
Overrides Plain Override Solenoid Ends
Coil Rating Code B
Electrical Options None
Reducer Module Code None
Manual Override Plain Override
Function 3-Position Spring Centered
Operation Pilot Operated
Surge Suppressor/Damper Code None
Pressure [Max] 5000 psi
Center Position All Ports Blocked
Surge Suppressor/Damper None
Pilot Pressure [Max] 3000 psi
Weight 100.0 LB