- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Model No. | DG5V-8-H-8C-VM-FW-B-10 |
| Electrical Options Code | None |
| Overrides | Plain Override Solenoid Ends |
| EN Code | None |
| Spool Indicator Switch Code | None |
| NFPA Size | D08 |
| Pilot Drain Code | None |
| Solenoid | Double |
| Pressure [Max] | 5000 psi |
| Pilot Valve Type | CETOP 3, High Performance |
| No. of Stages | Two Stage |
| Tank Port Rating | 5000 |
| Pressure Port Check Valve Code | None |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Surge Suppressor/Damper Code | None |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Coil Type Code | F |
| Mechanical Options Code | None |
| Gauge Port | SAE-4 |
| Port Restrictor Plugs | None |
| Mounting | Subplate/Manifold Mount |
| Compatible Fluids | Petroleum Oil |
| Pressure Port Check Valve Pressure | N/A |
| Actuator Type | Solenoid |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Housing Code | W |
| Pilot Valve Type Code | H |
| Mechanical Options | None |
| Center Position | P to T, A & B Blocked |
| Seal Material | Buna-N |
| Reducer Module | No |
| Fluid Cleanliness | 19/17/14 micron |
| Electrical Connection | No Connector |
| Body Material | Gray Iron |
| Surge Suppressor/Damper | None |
| Pilot/Drain | External Pilot/Internal Drain |
| Gauge Ports Code | None |
| AC/DC | AC |
| Electrical Options | None |
| Coil Rating Code | B |
| Crossover | All Ports Open, Restricted |
| Valve Type | Standard-Duty |
| Function | 3-Position Spring Centered |
| Port T Pressure Rating | 5000 psi |
| Solenoid Energization Code | V |
| Port Restrictor Plug Code | None |
| Manual Override | Plain Override |
| Electrical Connector Code | None |
| Spool Spring Arrangement Code | C |
| Rated Flow [Max] | 175 gal/min |
| Design No. | 10 |
| Response Type | Standard Response |
| Solenoid Indicator Lights Code | None |
| Performance | High Performance |
| Spool Control Modification Code | None |
| Response Type Code | None |
| Manual Override Option Code | None |
| Pilot Pressure Code | None |
| Spool Code | 8 |
| Indicator Lights | No |
| Spool Center Condition | A Port and Double Offset sensing switch on B Port |
| Operation | Pilot Operated |
| Leakage | Standard Performance |
| Reducer Module Code | None |
| Weight | 35.0 LB |