Vickers by Danfoss02-338228

02-338228

Vickers DG5V-8 Series Pilot Operated Solenoid Controlled Directional Valve
Item #102171885
  • Std-Duty D08 Pilot Op Dbl Sol Valve
  • Ctr: P & B Blocked, A to T
  • 3-Pos Spring Ctr
  • 110/120 VAC - 50/60 Hz
  • Flying Leads, 1/2 NPT Thread Hsg
  • Wired Terminal Block
  • CETOP 3, Std Performance Pilot
  • Int Pilot / Ext Drain
  • Plain Override Solenoid Ends
+ Show More + Show Less
Vickers by Danfoss02-338228
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Std-Duty D08 Pilot Op Dbl Sol Valve
  • Ctr: P & B Blocked, A to T
  • 3-Pos Spring Ctr
  • 110/120 VAC - 50/60 Hz
  • Flying Leads, 1/2 NPT Thread Hsg

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Plastic cushion grips are intended for comfort and do not protect from electrical shock
Housing Code W
Overrides Plain Override Solenoid Ends
Spool Spring Arrangement Code C
Actuator Type Solenoid
Electrical Connector Code T
Electrical Connection Wired Terminal Block
Seal Material Buna-N
AC/DC AC
Solenoid Indicator Lights Code L
Surge Suppressor/Damper None
Electrical Options None
Crossover All Ports Blocked, or P & B Blocked, A to T
Manual Override Option Code None
Voltage & Frequency 110/120 VAC – 50/60 Hz
Port T Pressure Rating 5000 psi
Pilot Valve Type Code S
NFPA Size D08
Center Position P & B Blocked, A to T
Mechanical Options Code None
Spool Control Modification Code 3
Reducer Module N/A
Electrical Options Code None
Spool Indicator Switch Code None
Pilot Valve Type CETOP 3, Standard Performance
Surge Suppressor/Damper Code None
Pilot/Drain Internal Pilot/External Drain
Gauge Port SAE-4
Response Type Standard Response
Pressure [Max] 5000 psi
Design No. 10
Pilot Pressure Code None
EN Code None
Port Restrictor Plug Code None
Mechanical Options Adjust Pilot Chokes on Both Ends, Adjust Stroke on Both Ends
Response Type Code None
Coil Type Code F
Pilot Drain Code None
Pressure Port Check Valve Pressure N/A
Valve Type Standard-Duty
Port Restrictor Plugs None
Operation Pilot Operated
Function 3-Position Spring Centered
Solenoid Double
Reducer Module Code None
Coil Rating Code B
Spool Code 3
Rated Flow [Max] 185 gal/min
Indicator Lights Yes
Coil Type Flying Leads, 1/2 NPT Thread Wiring Housing
Gauge Ports Code None
Pressure Port Check Valve Code None
Solenoid Energization Code None
Weight 35.0 LB