- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Detented Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Body Material | Ductile Iron |
| Spool Indicator Switch Code | None |
| Surge Suppressor/Damper | None |
| Pilot Valve Type Code | S |
| Manual Override | Plain Override |
| Performance | Standard Performance |
| Spool Control Modification Code | 2 |
| Seal Material | Buna-N |
| Manual Override Option Code | None |
| Pressure Port Check Valve Code | None |
| NFPA Size | D08 |
| Mechanical Options Code | None |
| Temperature Range [Min] | -40 °F |
| Solenoid | Double |
| Overrides | Plain Override Solenoid Ends |
| Response Type | Standard Response |
| Spool Spring Arrangement Code | N |
| Actuation Identification | Solenoid A, Solenoid B |
| Indicator Lights | Yes |
| Pilot Valve Type | CETOP 3, Standard Performance |
| Model No. | DG5V-8-S-6N-2-M-FTWL-B-10 |
| Compatible Fluids | Petroleum Oil |
| Fluid Cleanliness | 19/17/14 micron |
| Response Type Code | None |
| Function | 3-Position Detented |
| Coil Type Code | F |
| Actuator Type | Solenoid |
| Pilot/Drain | Internal Pilot/External Drain |
| Gauge Ports Code | None |
| Pressure [Max] | 5000 psi |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Pressure Port Check Valve Pressure | N/A |
| Spool Code | 6 |
| No. of Stages | Two Stage |
| Reducer Module Code | None |
| Pilot Drain Code | None |
| Crossover | P Blocked, A or B to T |
| Rated Flow [Max] | 175 gal/min |
| Electrical Connection | Wired Terminal Block |
| Port T Pressure Rating | 5000 psi |
| Valve Type | Standard-Duty |
| Mechanical Options | Adjust Pilot Chokes on Both Ends |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Mounting | Subplate/Manifold Mount |
| AC/DC | AC |
| Operation | Pilot Operated |
| Tank Port Rating | 5000 |
| Housing Code | W |
| Electrical Options Code | None |
| Center Position | P Blocked, A & B to T |
| Reducer Module | No |
| Pilot Pressure Code | None |
| Gauge Port | SAE-4 |
| Solenoid Indicator Lights Code | L |
| Electrical Options | None |
| Temperature Range [Max] | 230 °F |
| Leakage | Standard Performance |
| Coil Rating Code | B |
| Port Restrictor Plug Code | None |
| Surge Suppressor/Damper Code | None |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Design No. | 10 |
| EN Code | None |
| Solenoid Energization Code | None |
| Port Restrictor Plugs | None |
| Electrical Connector Code | T |
| Weight | 35.0 LB |