Skip to content Skip to navigation menu
Vickers by Danfoss02-337198

02-337198

Vickers D10 Solenoid Valve
Item #101966399
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-337198
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D10 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

applications

  • Used to control large flows, to 1,100 l/min (290 US gpm)

features

  • Offers a wide variety spool and spring arrangements, pilot choke adjustments, integral check valves, and port orifices to meet most system requirements
  • High force solenoids and centering springs ensure consistent shifting through a wide range of pressure and silting extremes
  • Endurance tested to 10 million cycles and fatigue tested to NFPA specifications without failure to ensure the highest reliability in applications requiring high flows and pressure
  • Valve has been computer flow modeled in the core passages of the solid cast body to provide maximum flow at the lowest possible pressure drop
NFPA Size D10
Solenoid Energization Code None
Model No. DG5V-10-S-6C-M-U-B-10
Seal Material Buna-N
Operation Pilot Operated
EN Code None
Port T Pressure Rating 3000 psi
Valve Type Standard-Duty
Response Type Standard Response
Design No. 10
Coil Type Code U
Pressure Port Check Valve Pressure N/A
Reducer Module N/A
Response Type Code None
Manual Override Plain Override
Indicator Lights No
Actuator Type Solenoid
Housing Code None
Pilot Pressure [Max] 3000 psi
Coil Type DIN 43650
Pilot Drain Code None
Reducer Module Code None
Surge Suppressor/Damper Code None
Pressure Port Check Valve Code None
Mechanical Options None
Center Position P Blocked, A & B to T
Electrical Options None
Electrical Connector Code None
Surge Suppressor/Damper None
Crossover P Blocked, A or B to T
Pilot Valve Type Code S
Overrides Plain Override Solenoid Ends
Electrical Options Code None
Function 3-Position Spring Centered
Spool Control Modification Code None
Pilot Pressure Code None
Spool Code 6
Tank Port Rating 3000
Voltage & Frequency 110/120 VAC - 50/60 Hz
Port Restrictor Plug Code None
AC/DC AC
Electrical Connection No Connector
Pilot Valve Type CETOP 3, Standard Performance
Assembly Code None
Manual Override Option Code None
Rated Flow [Max] 290 gal/min
Solenoid Indicator Lights Code None
Spool Spring Arrangement Code C
Gauge Port SAE-4
Pilot/Drain External Pilot/Internal Drain
Coil Rating Code B
Solenoid Double
Port Restrictor Plugs None
Gauge Ports Code None
Pressure [Max] 5000 psi
Weight 100.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison