Skip to content Skip to navigation menu
Vickers D03 Solenoid Valve

02-336477

Vickers D03 Solenoid Valve
Item #101912659
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • For directing and stopping flow at any point in a hydraulic system. Its primary function is to determine the direction of fluid flow in a work cylinder or control the direction of rotation of a fluid motor. Port connections are made by mounting the valve on a subplate or manifold. The valve has wet armature type solenoids. It is derived from the standard model series DG4V-3S-60.

features

  • Minimal pressure drop
  • Scratch-proof override seals
  • Tank line can withstand pressures up to 210 bar (3,000 psi)
  • High thermal shock and impact resistance due to new coil design
  • Multiple electrical connections
  • High reliability

compliances

  • 0
Valve Type Standard-Duty for Mobile Equipment
Electrical Connection DIN 43650
Port T Code 7
Body Material Gray Iron
Function Code 6
Spool Code 6
Seal Material Viton
Solenoid Double
Mounting Subplate/Manifold Mount
AC/DC DC
No. of Stages Single Stage
Performance Standard Performance
Pressure [Max] 5000 psi
Reducer Module No
Spool Center Condition A Port and Double Offset sensing switch on B Port
Compatible Fluids Phosphate Ester Fluids
Pressure Port Check Valve Pressure N/A
Mechanical Options None
Manual Override Option Code None
Watt Rating 30 W
Response Type Standard Response
Solenoid Code H
Overrides No Overrides
Surge Suppressor/Damper None
Fluid Cleanliness 19/17/14 micron
Voltage & Frequency 24 VDC
Rated Flow [Max] 10 gal/min
Coil Type Code U
Spool Indicator Switch Code None
Design No. 60
Port T Pressure Rating 3000 psi
Solenoid Indicator Lights Code None
Port Restrictor Plug Code None
NFPA Size D03
Leakage Standard Performance
Pilot Valve Type N/A
Tank Port Rating 3046
Function 3-Position Spring Centered
Housing Code None
Temperature Range [Max] 158 °F
Model No. DG4V-3S-6C-M-U-H7-60-EN490
Port Restrictor Plugs None
EN Code EN490
Coil Type ISO 4400 (Din 43650) Connector
Cycle Rate [Max] N/A
Crossover P Blocked, A or B to T
Electrical Options None
Manual Override Plain Override
Surge Suppressor/Damper Code None
Indicator Lights No
Coil Rating Code H
Center Position P Blocked, A & B to T
Actuator Type Solenoid
Spool Shift Timing N/A
Operation Solenoid Operated
Temperature Range [Min] -4 °F
Solenoid Energization Code None
Spool Spring Arrangement Code C
Pilot/Drain None
Electrical Connector Code None
Weight 5.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle