- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Operation | Pilot Operated |
| Gauge Ports Code | None |
| Reducer Module | No |
| Compatible Fluids | Petroleum Oil |
| Model No. | DG5V-8-H-0C-M-FW-B-10 |
| Pressure [Max] | 5000 psi |
| Response Type Code | None |
| Overrides | Plain Override Solenoid Ends |
| Pilot/Drain | External Pilot/Internal Drain |
| EN Code | None |
| Port Restrictor Plugs | None |
| Crossover | All Ports Open |
| Temperature Range [Min] | -40 °F |
| Spool Indicator Switch Code | None |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Spool Code | 0 |
| Pilot Valve Type Code | H |
| Pilot Pressure Code | None |
| Surge Suppressor/Damper Code | None |
| Leakage | High Performance |
| Coil Type Code | F |
| Actuator Type | Solenoid |
| Housing Code | W |
| Port Restrictor Plug Code | None |
| Electrical Connector Code | None |
| Spool Control Modification Code | None |
| Valve Type | Standard-Duty |
| Electrical Connection | No Connector |
| Manual Override Option Code | None |
| Temperature Range [Max] | 230 °F |
| Mounting | Subplate/Manifold Mount |
| Center Position | All Ports Open |
| Rated Flow [Max] | 175 gal/min |
| Design No. | 10 |
| Surge Suppressor/Damper | None |
| Actuation Identification | Solenoid A, Solenoid B |
| Mechanical Options Code | None |
| Function | 3-Position Spring Centered |
| Indicator Lights | No |
| Gauge Port | SAE-4 |
| Solenoid Energization Code | None |
| Pressure Port Check Valve Code | None |
| Reducer Module Code | None |
| Pressure Port Check Valve Pressure | N/A |
| Manual Override | Plain Override |
| Pilot Drain Code | None |
| Coil Rating Code | B |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Solenoid | Double |
| Fluid Cleanliness | 19/17/14 micron |
| Response Type | Standard Response |
| Body Material | Ductile Iron |
| AC/DC | AC |
| Solenoid Indicator Lights Code | None |
| Seal Material | Buna-N |
| Electrical Options Code | None |
| Electrical Options | None |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Port T Pressure Rating | 5000 psi |
| Spool Spring Arrangement Code | C |
| NFPA Size | D08 |
| Tank Port Rating | 5000 |
| Pilot Valve Type | CETOP 3, High Performance |
| No. of Stages | Two Stage |
| Mechanical Options | None |
| Performance | High Performance |
| Weight | 35.0 LB |