- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- It is necessary to use a minimum of one flanged pulley to prevent the belt from riding off
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
| Pilot Valve Type | CETOP 3, Standard Performance |
| Temperature Range [Min] | -40 °F |
| Performance | Standard Performance |
| Mechanical Options Code | None |
| Spool Control Modification Code | None |
| Seal Material | Buna-N |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Surge Suppressor/Damper Code | None |
| Spool Code | 8 |
| Design No. | 10 |
| Tank Port Rating | 5000 |
| AC/DC | AC |
| Center Position | P to T, A & B Blocked |
| Fluid Cleanliness | 19/17/14 micron |
| Solenoid Energization Code | V |
| Function | 3-Position Spring Centered |
| Manual Override | Plain Override |
| Gauge Port | SAE-4 |
| Body Material | Ductile Iron |
| Reducer Module Code | None |
| Compatible Fluids | Petroleum Oil |
| Electrical Options Code | None |
| Response Type Code | None |
| Housing Code | None |
| Pressure [Max] | 5000 psi |
| Pilot Valve Type Code | S |
| Pilot Pressure Code | None |
| Crossover | All Ports Open, Restricted |
| Response Type | Standard Response |
| Mounting | Subplate/Manifold Mount |
| Port Restrictor Plug Code | None |
| Spool Spring Arrangement Code | C |
| Pressure Port Check Valve Pressure | N/A |
| EN Code | None |
| Port T Pressure Rating | 5000 psi |
| Port Restrictor Plugs | None |
| Pressure Port Check Valve Code | None |
| Gauge Ports Code | None |
| Solenoid | Double |
| Valve Type | Standard-Duty |
| Coil Type | ISO 4400 (Din 43650) Connector |
| Mechanical Options | None |
| Solenoid Indicator Lights Code | None |
| Surge Suppressor/Damper | None |
| Indicator Lights | No |
| Leakage | Standard Performance |
| Coil Rating Code | D |
| Voltage & Frequency | 220/240 VAC - 50/60 Hz |
| Pilot/Drain | Internal Pilot/External Drain |
| Electrical Connection | No Connector |
| Electrical Options | None |
| Actuator Type | Solenoid |
| Model No. | DG5V-8-S-8C-VM-U-D-10 |
| Rated Flow [Max] | 175 gal/min |
| Overrides | Plain Override Solenoid Ends |
| Reducer Module | No |
| Electrical Connector Code | None |
| Spool Indicator Switch Code | None |
| NFPA Size | D08 |
| Coil Type Code | U |
| Temperature Range [Max] | 230 °F |
| Manual Override Option Code | None |
| Actuation Identification | Solenoid A, Solenoid B |
| Pilot Drain Code | None |
| Operation | Pilot Operated |
| No. of Stages | Two Stage |
| Weight | 35.0 LB |