Vickers by Danfoss02-329264

02-329264

Vickers D08 Solenoid Valve
Item #102083938
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329264
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Cannot be used in air systems where compressors are lubricated with fire-resistant fluids, such as phosphate ester and di-ester types
Pressure Port Check Valve Pressure N/A
Actuator Type Solenoid
Tank Port Rating 5000
Gauge Port SAE-4
Compatible Fluids Petroleum Oil
EN Code None
Operation Pilot Operated
Pilot Valve Type CETOP 3, Standard Performance
Temperature Range [Min] -40 °F
Design No. 10
Temperature Range [Max] 230 °F
Reducer Module No
Mechanical Options Code None
Spool Indicator Switch Code None
Reducer Module Code None
Surge Suppressor/Damper Code None
Surge Suppressor/Damper None
Pressure [Max] 5000 psi
Response Type Code None
Pilot/Drain External Pilot/External Drain
Electrical Options None
Electrical Connector Code T
Pilot Valve Type Code S
Coil Type Code F
NFPA Size D08
Indicator Lights Yes
Port Restrictor Plug Code None
Gauge Ports Code None
Manual Override Plain Override
Port Restrictor Plugs None
Performance Standard Performance
Pressure Port Check Valve Code None
Valve Type Standard-Duty
Model No. DG5V-8-S-8C-E-VM-FTWL-B-10
Fluid Cleanliness 19/17/14 micron
Leakage Standard Performance
Mounting Subplate/Manifold Mount
Port T Pressure Rating 5000 psi
No. of Stages Two Stage
Actuation Identification Solenoid A, Solenoid B
Electrical Options Code None
Manual Override Option Code None
Response Type Standard Response
Spool Control Modification Code None
Electrical Connection Wired Terminal Block
Mechanical Options None
Pilot Drain Code None
Solenoid Double
Crossover All Ports Open, Restricted
Pilot Pressure Code E
Solenoid Indicator Lights Code L
Rated Flow [Max] 175 gal/min
Function 3-Position Spring Centered
Spool Spring Arrangement Code C
AC/DC AC
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Housing Code W
Voltage & Frequency 110/120 VAC - 50/60 Hz
Overrides Plain Override Solenoid Ends
Center Position P to T, A & B Blocked
Seal Material Buna-N
Body Material Ductile Iron
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Coil Rating Code B
Spool Code 8
Solenoid Energization Code V
Weight 35.0 LB