Vickers by Danfoss02-329238

02-329238

Vickers D08 Solenoid Valve
Item #101971263
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329238
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Standard, QD-style HTD sprockets may not have the torque capacity for the higher rated HT150 belts.
Pilot Drain Code T
Solenoid Indicator Lights Code None
Seal Material Buna-N
Pilot Valve Type Code S
Indicator Lights No
Gauge Ports Code None
Reducer Module Code None
Pilot/Drain Internal Pilot/Internal Drain
Electrical Connector Code None
Pressure Port Check Valve Code None
Model No. DG5V-8-S-31C-T-M-U-H-10
Spool Spring Arrangement Code C
Port Restrictor Plug Code None
Spool Indicator Switch Code None
Pressure [Max] 5000 psi
Housing Code None
Solenoid Energization Code None
Operation Pilot Operated
Mechanical Options Code None
Solenoid Double
Electrical Connection No Connector
Mechanical Options None
Crossover All Ports Blocked
Pressure Port Check Valve Pressure N/A
Coil Rating Code H
Overrides Plain Override Solenoid Ends
Port T Pressure Rating 5000 psi
EN Code None
Response Type Code None
AC/DC DC
Reducer Module N/A
Valve Type Standard-Duty
Port Restrictor Plugs None
Manual Override Option Code None
Tank Port Rating 5000
Spool Control Modification Code None
Coil Type DIN 43650
Function 3-Position Spring Centered
Response Type Standard Response
Surge Suppressor/Damper None
Electrical Options None
Pilot Pressure Code None
Spool Code 31
Gauge Port SAE-4
Design No. 10
Surge Suppressor/Damper Code None
Electrical Options Code None
Rated Flow [Max] 185 gal/min
Pilot Valve Type CETOP 3, Standard Performance
Actuator Type Solenoid
Center Position P & A Blocked, B to T
NFPA Size D08
Coil Type Code U
Voltage & Frequency 24 VDC
Manual Override Plain Override
Weight 35.0 LB