- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Detented Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Pilot Valve Type | CETOP 3, Standard Performance |
| Model No. | DG5V-8-S-2N-M-FW-B-10 |
| Tank Port Rating | 5000 |
| Solenoid Indicator Lights Code | None |
| Temperature Range [Min] | -40 °F |
| Leakage | Standard Performance |
| Gauge Port | SAE-4 |
| Spool Indicator Switch Code | None |
| Overrides | Plain Override Solenoid Ends |
| Reducer Module Code | None |
| Pressure Port Check Valve Pressure | N/A |
| Center Position | All Ports Blocked |
| Spool Control Modification Code | None |
| Port Restrictor Plug Code | None |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Electrical Options Code | None |
| Actuator Type | Solenoid |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Compatible Fluids | Petroleum Oil |
| Pressure Port Check Valve Code | None |
| Coil Type Code | F |
| Reducer Module | No |
| Pilot/Drain | External Pilot/Internal Drain |
| Response Type | Standard Response |
| Manual Override Option Code | None |
| Seal Material | Buna-N |
| NFPA Size | D08 |
| Valve Type | Standard-Duty |
| Housing Code | W |
| Electrical Connection | No Connector |
| Performance | Standard Performance |
| Operation | Pilot Operated |
| Electrical Connector Code | None |
| Gauge Ports Code | None |
| EN Code | None |
| Electrical Options | None |
| Response Type Code | None |
| Design No. | 10 |
| Pilot Drain Code | None |
| Body Material | Ductile Iron |
| Pressure [Max] | 5000 psi |
| Fluid Cleanliness | 19/17/14 micron |
| Crossover | All Ports Blocked |
| Pilot Valve Type Code | S |
| Coil Rating Code | B |
| Manual Override | Plain Override |
| Port T Pressure Rating | 5000 psi |
| Actuation Identification | Solenoid A, Solenoid B |
| Solenoid | Double |
| AC/DC | AC |
| Mechanical Options | None |
| Mounting | Subplate/Manifold Mount |
| Indicator Lights | No |
| Temperature Range [Max] | 230 °F |
| Surge Suppressor/Damper | None |
| No. of Stages | Two Stage |
| Spool Code | 2 |
| Spool Center Condition | A Port and Double Offset sensing switch on B Port |
| Rated Flow [Max] | 175 gal/min |
| Surge Suppressor/Damper Code | None |
| Function | 3-Position Detented |
| Spool Spring Arrangement Code | N |
| Port Restrictor Plugs | None |
| Solenoid Energization Code | None |
| Mechanical Options Code | None |
| Pilot Pressure Code | None |
| Weight | 35.0 LB |