description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Spool Indicator Switch Code None
EN Code None
Solenoid Energization Code None
AC/DC AC
Rated Flow [Max] 175 gal/min
Gauge Port SAE-4
Pilot Valve Type CETOP 3, Standard Performance
Mechanical Options Code None
Reducer Module Code None
Spool Code 6
Temperature Range [Min] -40 °F
Actuation Identification Solenoid A, Solenoid B
Pressure [Max] 5000 psi
Mechanical Options None
Electrical Connector Code T
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Temperature Range [Max] 230 °F
Operation Pilot Operated
NFPA Size D08
Housing Code W
Electrical Options None
Pressure Port Check Valve Pressure N/A
Tank Port Rating 5000
Model No. DG5V-8-S-6C-T-M-FTWL-B-10
Pressure Port Check Valve Code None
Port Restrictor Plugs None
Voltage & Frequency 110/120 VAC - 50/60 Hz
Reducer Module No
Overrides Plain Override Solenoid Ends
Electrical Options Code None
Spool Control Modification Code None
Center Position P Blocked, A & B to T
Actuator Type Solenoid
Pilot Drain Code T
Indicator Lights Yes
Response Type Standard Response
Mounting Subplate/Manifold Mount
Body Material Ductile Iron
Spool Spring Arrangement Code C
Surge Suppressor/Damper None
Manual Override Option Code None
Electrical Connection Wired Terminal Block
Solenoid Indicator Lights Code L
Function 3-Position Spring Centered
Compatible Fluids Petroleum Oil
Pilot Pressure Code None
Port Restrictor Plug Code None
Valve Type Standard-Duty
Manual Override Plain Override
Port T Pressure Rating 5000 psi
Pilot/Drain External Pilot/Internal Drain
Coil Type Code F
Coil Rating Code B
Fluid Cleanliness 19/17/14 micron
Performance Standard Performance
Leakage Standard Performance
No. of Stages Two Stage
Crossover P Blocked, A or B to T
Design No. 10
Solenoid Double
Seal Material Buna-N
Response Type Code None
Pilot Valve Type Code S
Gauge Ports Code None
Surge Suppressor/Damper Code None
Weight 35.0 LB