Skip to content Skip to navigation menu
Vickers by Danfoss02-329167

02-329167

Vickers D08 Solenoid Valve
Item #101985156
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329167
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Port Restrictor Plug Code None
Voltage & Frequency 110/120 VAC - 50/60 Hz
EN Code None
AC/DC AC
Spool Spring Arrangement Code C
Manual Override Plain Override
Valve Type Standard-Duty
Mechanical Options Code None
Electrical Options Code None
Pressure Port Check Valve Code None
Electrical Connection No Connector
Operation Pilot Operated
Response Type Standard Response
Gauge Port SAE-4
Actuator Type Solenoid
Function 3-Position Spring Centered
Housing Code W
Center Position P Blocked, A & B to T
Solenoid Energization Code None
Pressure Port Check Valve Pressure N/A
Surge Suppressor/Damper Code None
Compatible Fluids Petroleum Oil
Spool Center Condition A Port and Double Offset sensing switch on B Port
Indicator Lights No
Pressure [Max] 5000 psi
Design No. 10
Tank Port Rating 5000
NFPA Size D08
Pilot Valve Type CETOP 3, Standard Performance
Body Material Gray Iron
Reducer Module No
Pilot Pressure Code None
Electrical Connector Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Rated Flow [Max] 175 gal/min
Pilot Valve Type Code S
Port Restrictor Plugs None
Surge Suppressor/Damper None
Response Type Code None
Gauge Ports Code None
Port T Pressure Rating 5000 psi
Spool Code 6
Solenoid Double
Leakage Standard Performance
Manual Override Option Code None
Electrical Options None
Model No. DG5V-8-S-6C-M-FW-B-10
Solenoid Indicator Lights Code None
Pilot/Drain External Pilot/Internal Drain
Mounting Subplate/Manifold Mount
Mechanical Options None
Seal Material Buna-N
Crossover P Blocked, A or B to T
Coil Rating Code B
Spool Indicator Switch Code None
Reducer Module Code None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Overrides Plain Override Solenoid Ends
Pilot Drain Code None
Performance Standard Performance
Fluid Cleanliness 19/17/14 micron
Spool Control Modification Code None
No. of Stages Two Stage
Coil Type Code F
Weight 35.0 LB
We're here for you
with Service Centers across the country -
We have your back
Close Compare List Open Compare List Toggle

Product Comparison